Preconcentration and measurement of trace Amitriptyline hydrochloride in water samples using magnetic nanoparticles with dispersive solid-phase extraction
IF 1.5 4区 材料科学Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY
{"title":"Preconcentration and measurement of trace Amitriptyline hydrochloride in water samples using magnetic nanoparticles with dispersive solid-phase extraction","authors":"Arghavan Amin, Ali Moghimi","doi":"10.1049/mna2.12184","DOIUrl":null,"url":null,"abstract":"<p>In the separation and determination of trace amounts of drugs in aqueous samples, there is a major challenge in synthesizing highly efficient, cost-effective, and easy-to-use adsorbents based on natural polymers, which are also biocompatible and biodegradable. In the proposed method, magnetite nanoparticles (Fe<sub>3</sub>O<sub>4</sub>) on chitosan (as the carrier) modified with β-cyclodextrin (BCD) were used as a suitable adsorbent for the pre-concentration and solid-phase extraction of trace amounts of Amitriptyline HCl (hydrochloride). Ultraviolet spectrophotometer (λ = 236 nm) was the main instrument used for analyte detection and quantification. Moreover, X-ray diffraction, Fourier transform infrared spectroscopy, Field Emission Scanning Electron Microscopy, and Energy-Dispersive X-ray were used for the identification and characterization of the structure and morphology of the adsorbent and to establish the formation of the synthesized magnetic nanosorbents, as well as to confirm the analyte binding to the adsorbent. Experimental variables affecting the extraction/pre-concentration and determination of the analyte were investigated and optimized; pH of the sample solution, the amount of NaCl salt (in terms of ionic strength of the solution), the amount of adsorbent, temperature, adsorption time, and volume of the eluent (methanol) were the optimized parameters. Finally, the method was successfully applied for the determination of spiked Amitriptyline hydrochloride (HCl) in tap water and human urine samples. Also, High-Performance Liquid Chromatography was performed on the aqueous samples to compare the proposed method with the USP (the United States Pharmacopeia) standard method of Amitriptyline HCl assay and after performing a <i>t</i>-test (confidence level of 95%), no significant difference was observed between the two methods. High accuracy and precision (RSD = 3.91%), High analysis speed, few limitations, low expenses, pure extracted analyte, and low waste were the advantages of this method. This method was also compatible with many existing device methods. Under the optimized experimental conditions, the calibration graph was linear in the range of 0.183 to 50 mg.L<sup>−1</sup> with a correlation coefficient of 0.996. RSD of the method was 3.91%, the limit of detection was 37.8 µg.L<sup>−1</sup>, the maximum sorption capacity of the adsorbent for Amitriptyline hydrochloride was 306.525 mg.g<sup>−1</sup> and the preconcentration factor was 3.61. Eventually, the proposed method was compared to other methods that have been performed for the determination of Amitriptyline hydrochloride.</p>","PeriodicalId":18398,"journal":{"name":"Micro & Nano Letters","volume":"19 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2023-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/mna2.12184","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micro & Nano Letters","FirstCategoryId":"88","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/mna2.12184","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
In the separation and determination of trace amounts of drugs in aqueous samples, there is a major challenge in synthesizing highly efficient, cost-effective, and easy-to-use adsorbents based on natural polymers, which are also biocompatible and biodegradable. In the proposed method, magnetite nanoparticles (Fe3O4) on chitosan (as the carrier) modified with β-cyclodextrin (BCD) were used as a suitable adsorbent for the pre-concentration and solid-phase extraction of trace amounts of Amitriptyline HCl (hydrochloride). Ultraviolet spectrophotometer (λ = 236 nm) was the main instrument used for analyte detection and quantification. Moreover, X-ray diffraction, Fourier transform infrared spectroscopy, Field Emission Scanning Electron Microscopy, and Energy-Dispersive X-ray were used for the identification and characterization of the structure and morphology of the adsorbent and to establish the formation of the synthesized magnetic nanosorbents, as well as to confirm the analyte binding to the adsorbent. Experimental variables affecting the extraction/pre-concentration and determination of the analyte were investigated and optimized; pH of the sample solution, the amount of NaCl salt (in terms of ionic strength of the solution), the amount of adsorbent, temperature, adsorption time, and volume of the eluent (methanol) were the optimized parameters. Finally, the method was successfully applied for the determination of spiked Amitriptyline hydrochloride (HCl) in tap water and human urine samples. Also, High-Performance Liquid Chromatography was performed on the aqueous samples to compare the proposed method with the USP (the United States Pharmacopeia) standard method of Amitriptyline HCl assay and after performing a t-test (confidence level of 95%), no significant difference was observed between the two methods. High accuracy and precision (RSD = 3.91%), High analysis speed, few limitations, low expenses, pure extracted analyte, and low waste were the advantages of this method. This method was also compatible with many existing device methods. Under the optimized experimental conditions, the calibration graph was linear in the range of 0.183 to 50 mg.L−1 with a correlation coefficient of 0.996. RSD of the method was 3.91%, the limit of detection was 37.8 µg.L−1, the maximum sorption capacity of the adsorbent for Amitriptyline hydrochloride was 306.525 mg.g−1 and the preconcentration factor was 3.61. Eventually, the proposed method was compared to other methods that have been performed for the determination of Amitriptyline hydrochloride.
期刊介绍:
Micro & Nano Letters offers express online publication of short research papers containing the latest advances in miniature and ultraminiature structures and systems. With an average of six weeks to decision, and publication online in advance of each issue, Micro & Nano Letters offers a rapid route for the international dissemination of high quality research findings from both the micro and nano communities.
Scope
Micro & Nano Letters offers express online publication of short research papers containing the latest advances in micro and nano-scale science, engineering and technology, with at least one dimension ranging from micrometers to nanometers. Micro & Nano Letters offers readers high-quality original research from both the micro and nano communities, and the materials and devices communities.
Bridging this gap between materials science and micro and nano-scale devices, Micro & Nano Letters addresses issues in the disciplines of engineering, physical, chemical, and biological science. It places particular emphasis on cross-disciplinary activities and applications.
Typical topics include:
Micro and nanostructures for the device communities
MEMS and NEMS
Modelling, simulation and realisation of micro and nanoscale structures, devices and systems, with comparisons to experimental data
Synthesis and processing
Micro and nano-photonics
Molecular machines, circuits and self-assembly
Organic and inorganic micro and nanostructures
Micro and nano-fluidics