Color Mapping using Ultrasound System-integrated Perfusion Software for Evaluation of Focal Liver Lesions: A Possible First Step for More Independent Reading.
Ivor Dropco, Ulrich Kaiser, Lola Wagner, Stefan M Brunner, Hans Jürgen Schlitt, Christian Stroszcynski, Friedrich Jung, Dong Yi, Wolfgang Herr, Ernst Michael Jung
{"title":"Color Mapping using Ultrasound System-integrated Perfusion Software for Evaluation of Focal Liver Lesions: A Possible First Step for More Independent Reading.","authors":"Ivor Dropco, Ulrich Kaiser, Lola Wagner, Stefan M Brunner, Hans Jürgen Schlitt, Christian Stroszcynski, Friedrich Jung, Dong Yi, Wolfgang Herr, Ernst Michael Jung","doi":"10.15403/jgld-4997","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To assess the value of using integrated parametric ultrasound software for contrast-enhanced ultrasonography (CEUS) of liver tumors.</p><p><strong>Methods: </strong>107 patients with liver tumors were studied. CEUS were performed to detect focal lesions. Parametric images were based on continuous CINE LOOPs, from the early-arterial phase (15 s) to the portal-venous phase (1 min) generated by perfusion software. The evaluations of the parametric images and their dignity for liver lesions were performed independently by an experienced and a less-experienced investigator. Computed tomography, magnetic resonance imaging scans or histological analysis were used as references.</p><p><strong>Results: </strong>High parametric image quality were obtained in all patients. Among the patients, 44% lesions were benign, 56% were malignant. The experienced investigator correctly classified 46 of 47 (98%) as benign, and 60 of 60 (100%) as malignant tumors based on the parametric images. The less-experienced investigator correctly classified 39 of 47 (83%) as benign, and 49 of 60 (82%) malignant tumors, acheaving a high statistical accuracy of 98% with this type of diagnostic.</p><p><strong>Conclusion: </strong>Parametric imaging for grading the malignant degree of tumor may be a good complement to existing ultrasound techniques and was particularly helpful for improving the assessments of the less-experienced examiner.</p>","PeriodicalId":94081,"journal":{"name":"Journal of gastrointestinal and liver diseases : JGLD","volume":"32 4","pages":"479-487"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of gastrointestinal and liver diseases : JGLD","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15403/jgld-4997","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: To assess the value of using integrated parametric ultrasound software for contrast-enhanced ultrasonography (CEUS) of liver tumors.
Methods: 107 patients with liver tumors were studied. CEUS were performed to detect focal lesions. Parametric images were based on continuous CINE LOOPs, from the early-arterial phase (15 s) to the portal-venous phase (1 min) generated by perfusion software. The evaluations of the parametric images and their dignity for liver lesions were performed independently by an experienced and a less-experienced investigator. Computed tomography, magnetic resonance imaging scans or histological analysis were used as references.
Results: High parametric image quality were obtained in all patients. Among the patients, 44% lesions were benign, 56% were malignant. The experienced investigator correctly classified 46 of 47 (98%) as benign, and 60 of 60 (100%) as malignant tumors based on the parametric images. The less-experienced investigator correctly classified 39 of 47 (83%) as benign, and 49 of 60 (82%) malignant tumors, acheaving a high statistical accuracy of 98% with this type of diagnostic.
Conclusion: Parametric imaging for grading the malignant degree of tumor may be a good complement to existing ultrasound techniques and was particularly helpful for improving the assessments of the less-experienced examiner.