Towards navigation in endoscopic kidney surgery based on preoperative imaging

IF 2.8 Q3 ENGINEERING, BIOMEDICAL
Ayberk Acar, Daiwei Lu, Yifan Wu, Ipek Oguz, Nicholas Kavoussi, Jie Ying Wu
{"title":"Towards navigation in endoscopic kidney surgery based on preoperative imaging","authors":"Ayberk Acar,&nbsp;Daiwei Lu,&nbsp;Yifan Wu,&nbsp;Ipek Oguz,&nbsp;Nicholas Kavoussi,&nbsp;Jie Ying Wu","doi":"10.1049/htl2.12059","DOIUrl":null,"url":null,"abstract":"<p>Endoscopic renal surgeries have high re-operation rates, particularly for lower volume surgeons. Due to the limited field and depth of view of current endoscopes, mentally mapping preoperative computed tomography (CT) images of patient anatomy to the surgical field is challenging. The inability to completely navigate the intrarenal collecting system leads to missed kidney stones and tumors, subsequently raising recurrence rates. A guidance system is proposed to estimate the endoscope positions within the CT to reduce re-operation rates. A Structure from Motion algorithm is used to reconstruct the kidney collecting system from the endoscope videos. In addition, the kidney collecting system is segmented from CT scans using 3D U-Net to create a 3D model. The two collecting system representations can then be registered to provide information on the relative endoscope position. Correct reconstruction and localization of intrarenal anatomy and endoscope position is demonstrated. Furthermore, a 3D map is created supported by the RGB endoscope images to reduce the burden of mental mapping during surgery. The proposed reconstruction pipeline has been validated for guidance. It can reduce the mental burden for surgeons and is a step towards the long-term goal of reducing re-operation rates in kidney stone surgery.</p>","PeriodicalId":37474,"journal":{"name":"Healthcare Technology Letters","volume":"11 2-3","pages":"67-75"},"PeriodicalIF":2.8000,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/htl2.12059","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Healthcare Technology Letters","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/htl2.12059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Endoscopic renal surgeries have high re-operation rates, particularly for lower volume surgeons. Due to the limited field and depth of view of current endoscopes, mentally mapping preoperative computed tomography (CT) images of patient anatomy to the surgical field is challenging. The inability to completely navigate the intrarenal collecting system leads to missed kidney stones and tumors, subsequently raising recurrence rates. A guidance system is proposed to estimate the endoscope positions within the CT to reduce re-operation rates. A Structure from Motion algorithm is used to reconstruct the kidney collecting system from the endoscope videos. In addition, the kidney collecting system is segmented from CT scans using 3D U-Net to create a 3D model. The two collecting system representations can then be registered to provide information on the relative endoscope position. Correct reconstruction and localization of intrarenal anatomy and endoscope position is demonstrated. Furthermore, a 3D map is created supported by the RGB endoscope images to reduce the burden of mental mapping during surgery. The proposed reconstruction pipeline has been validated for guidance. It can reduce the mental burden for surgeons and is a step towards the long-term goal of reducing re-operation rates in kidney stone surgery.

Abstract Image

基于术前成像的内镜肾脏手术导航
内窥镜肾脏手术的再手术率很高,尤其是对手术量较少的外科医生而言。由于目前内窥镜的视野和视深有限,将患者解剖结构的术前计算机断层扫描(CT)图像精确映射到手术区域具有挑战性。由于无法完全浏览肾内集合系统,导致漏诊肾结石和肿瘤,从而提高了复发率。我们提出了一种引导系统,用于估计 CT 中的内窥镜位置,以降低再次手术率。利用运动结构算法从内窥镜视频中重建肾脏收集系统。此外,还使用 3D U-Net 从 CT 扫描中分割肾脏收集系统,创建 3D 模型。然后,可对两个采集系统进行注册,以提供有关内窥镜相对位置的信息。肾内解剖结构和内窥镜位置的正确重建和定位得到了展示。此外,在 RGB 内窥镜图像的支持下还创建了三维地图,以减轻手术过程中心理绘图的负担。所提出的重建管道已通过指导验证。它可以减轻外科医生的心理负担,并朝着降低肾结石手术再手术率的长期目标迈进了一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Healthcare Technology Letters
Healthcare Technology Letters Health Professions-Health Information Management
CiteScore
6.10
自引率
4.80%
发文量
12
审稿时长
22 weeks
期刊介绍: Healthcare Technology Letters aims to bring together an audience of biomedical and electrical engineers, physical and computer scientists, and mathematicians to enable the exchange of the latest ideas and advances through rapid online publication of original healthcare technology research. Major themes of the journal include (but are not limited to): Major technological/methodological areas: Biomedical signal processing Biomedical imaging and image processing Bioinstrumentation (sensors, wearable technologies, etc) Biomedical informatics Major application areas: Cardiovascular and respiratory systems engineering Neural engineering, neuromuscular systems Rehabilitation engineering Bio-robotics, surgical planning and biomechanics Therapeutic and diagnostic systems, devices and technologies Clinical engineering Healthcare information systems, telemedicine, mHealth.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信