Reliability and validity of modified upper limb neurodynamic tests in patients with cervical radiculopathy

Pub Date : 2023-12-15 DOI:10.1142/s1013702524500112
Rupa Zanwar, S. Wani
{"title":"Reliability and validity of modified upper limb neurodynamic tests in patients with cervical radiculopathy","authors":"Rupa Zanwar, S. Wani","doi":"10.1142/s1013702524500112","DOIUrl":null,"url":null,"abstract":"Background: Neurodynamic Tests (NDTs) are used to assess neural mechanosensitivity in various conditions such as neural sliding, tension or inflammatory dysfunction. But in some upper quadrant dysfunctions, standard testing procedure of NDT cannot be assessed or tolerated by patient. Objective: The purpose of the study was to determine the validity, intra-rater and inter-rater reliability of modified NDTs via median and ulnar nerve in patients with cervical radiculopathy. Methods: Thirty-three patients (18 men and 15 women, mean age ± SD [Formula: see text]) with cervical radiculopathy having positive response to standard NDTs were included in the study. Modified neurodynamic tests for median & ulnar nerve were performed with modification in the sequencing of standard neurodynamic test at lower degrees of glenohumeral abduction and external rotation. Outcome measures used were angle of elbow extension for median nerve and angle elbow flexion for ulnar nerve at the point of pain onset indicated by “OP” (Onset of Pain). Results: Reliability of OP was evaluated using measurement of Intra-class Correlation Coefficient (ICC), Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) values. Results indicated high ICC values and low SEM values for OP during modified median and modified ulnar NDTs (M-MNT1 and M-UNT) on symptomatic side of patients with cervical radiculopathy. Spearman correlation analysis for validity of test score showed strong correlation ([Formula: see text]) with standard NDT. Conclusion: There was strong correlation between Modified NDTs and standard tests depicting good validity and substantial reliability of OP during M-MNT1 and M-UNT for positive NDT response in patients with cervical radiculopathy.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/s1013702524500112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Neurodynamic Tests (NDTs) are used to assess neural mechanosensitivity in various conditions such as neural sliding, tension or inflammatory dysfunction. But in some upper quadrant dysfunctions, standard testing procedure of NDT cannot be assessed or tolerated by patient. Objective: The purpose of the study was to determine the validity, intra-rater and inter-rater reliability of modified NDTs via median and ulnar nerve in patients with cervical radiculopathy. Methods: Thirty-three patients (18 men and 15 women, mean age ± SD [Formula: see text]) with cervical radiculopathy having positive response to standard NDTs were included in the study. Modified neurodynamic tests for median & ulnar nerve were performed with modification in the sequencing of standard neurodynamic test at lower degrees of glenohumeral abduction and external rotation. Outcome measures used were angle of elbow extension for median nerve and angle elbow flexion for ulnar nerve at the point of pain onset indicated by “OP” (Onset of Pain). Results: Reliability of OP was evaluated using measurement of Intra-class Correlation Coefficient (ICC), Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) values. Results indicated high ICC values and low SEM values for OP during modified median and modified ulnar NDTs (M-MNT1 and M-UNT) on symptomatic side of patients with cervical radiculopathy. Spearman correlation analysis for validity of test score showed strong correlation ([Formula: see text]) with standard NDT. Conclusion: There was strong correlation between Modified NDTs and standard tests depicting good validity and substantial reliability of OP during M-MNT1 and M-UNT for positive NDT response in patients with cervical radiculopathy.
分享
查看原文
颈椎病患者改良上肢神经动力测试的可靠性和有效性
背景:神经动力测试(NDT)用于评估神经滑动、紧张或炎症功能障碍等各种情况下的神经机械敏感性。但在某些上象限功能障碍中,神经动力测试的标准测试程序无法评估或患者无法耐受。研究目的本研究旨在确定颈椎病患者通过正中神经和尺神经进行改良无损检测的有效性、评分者内部和评分者之间的可靠性。研究方法研究纳入了 33 名对标准无损检测有积极反应的颈椎病患者(18 名男性和 15 名女性,平均年龄 ± SD [公式:见正文])。对正中神经和尺神经进行了改良神经动力测试,并在较低的盂肱外展和外旋程度下对标准神经动力测试的顺序进行了修改。结果测量指标为正中神经的伸肘角度和尺神经的屈肘角度,以 "OP"(疼痛发作)表示疼痛发作点。结果:通过测量类内相关系数(ICC)、测量标准误差(SEM)和最小可检测变化(MDC)值来评估 OP 的可靠性。结果表明,在颈椎病患者有症状的一侧进行改良正中和改良尺侧无损检测(M-MNT1 和 M-UNT)时,OP 的 ICC 值较高,SEM 值较低。对测试得分有效性的斯皮尔曼相关分析表明,测试得分与标准无损检测具有很强的相关性([公式:见正文])。结论改良无损检测与标准检测之间存在很强的相关性,说明在对颈椎病患者的无损检测反应进行阳性检测时,M-MNT1 和 M-UNT 的 OP 具有很好的有效性和很高的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信