{"title":"Energy Consumption Quality Indicators in Collector and Asynchronous Traction Drives of AC Electric Locomotives","authors":"A. Zarif'yan, A. Evstaf'ev","doi":"10.20295/1815-588x-2023-4-987-998","DOIUrl":null,"url":null,"abstract":"Purpose: To conduct an experimental study of the indicators of electrical energy consumption quality for serially produced freight electric locomotives of alternating current 2(3)ES5K with a collector traction drive and electric locomotives 2(3)ES5S with an asynchronous traction drive, to provide their comparison and comparative analysis. Methods: The main technical characteristics of the collector traction electric drive (TED) NB-514E and asynchronous TED DTA-1100 are presented. A measurement scheme for voltage and current on the power winding of the transformer is proposed. The monitoring of parameters has been carried out directly on electric locomotives using specialized metrological equipment. The processing of experimental data is based on decomposing the original signal into harmonic components using Fast Fourier Transform (FFT). Results: Parameters of voltage and current harmonics, phase shifts, as well as the values of active and reactive power of the corresponding harmonics have been obtained. An analysis of the spectral composition of voltage and current has been performed. Comparative analysis of the results obtained for electric locomotives with collector and asynchronous traction drives in traction mode has shown that the power factor is 0.65 and 0.99, respectively; and the coefficient of non-linear current distortions is 0.53 and 0.15. A conclusion has been drawn regarding significantly higher quality of electrical energy consumption in the asynchronous traction drive. Practical significance: Based on the specific values of the indicators of electrical energy consumption quality in collector and asynchronous traction drives in traction mode, it is possible to proceed to obtaining economic assessments for the transition of the locomotive fleet of Russian Railways (JSCo “RZD”) to nextgeneration electric locomotives of the 2(3)ES5S series.","PeriodicalId":273874,"journal":{"name":"Proceedings of Petersburg Transport University","volume":"4 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Petersburg Transport University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20295/1815-588x-2023-4-987-998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To conduct an experimental study of the indicators of electrical energy consumption quality for serially produced freight electric locomotives of alternating current 2(3)ES5K with a collector traction drive and electric locomotives 2(3)ES5S with an asynchronous traction drive, to provide their comparison and comparative analysis. Methods: The main technical characteristics of the collector traction electric drive (TED) NB-514E and asynchronous TED DTA-1100 are presented. A measurement scheme for voltage and current on the power winding of the transformer is proposed. The monitoring of parameters has been carried out directly on electric locomotives using specialized metrological equipment. The processing of experimental data is based on decomposing the original signal into harmonic components using Fast Fourier Transform (FFT). Results: Parameters of voltage and current harmonics, phase shifts, as well as the values of active and reactive power of the corresponding harmonics have been obtained. An analysis of the spectral composition of voltage and current has been performed. Comparative analysis of the results obtained for electric locomotives with collector and asynchronous traction drives in traction mode has shown that the power factor is 0.65 and 0.99, respectively; and the coefficient of non-linear current distortions is 0.53 and 0.15. A conclusion has been drawn regarding significantly higher quality of electrical energy consumption in the asynchronous traction drive. Practical significance: Based on the specific values of the indicators of electrical energy consumption quality in collector and asynchronous traction drives in traction mode, it is possible to proceed to obtaining economic assessments for the transition of the locomotive fleet of Russian Railways (JSCo “RZD”) to nextgeneration electric locomotives of the 2(3)ES5S series.
交流电力机车集电式和异步牵引传动装置的能耗质量指标
目的:对采用集电牵引传动的2(3)ES5K型交流传动货运电力机车和采用异步牵引传动的2(3)ES5S型电力机车的电能消耗质量指标进行试验研究,并进行对比分析。方法:介绍集电牵引电力传动装置(TED)NB-514E 和异步 TED DTA-1100 的主要技术特性。提出了变压器功率绕组电压和电流的测量方案。使用专门的计量设备直接在电力机车上进行参数监测。实验数据的处理基于使用快速傅立叶变换 (FFT) 将原始信号分解为谐波分量。结果:获得了电压和电流谐波的参数、相移以及相应谐波的有功和无功功率值。对电压和电流的频谱组成进行了分析。对采用集电式和异步牵引驱动装置的电力机车在牵引模式下获得的结果进行的比较分析表明,功率因数分别为 0.65 和 0.99;非线性电流畸变系数分别为 0.53 和 0.15。得出的结论是,异步牵引驱动装置的电能消耗质量明显更高。实际意义:根据牵引模式下集电极和异步牵引传动装置的电能消耗质量指标的具体值,可以着手对俄罗斯铁路公司(JSCo "RZD")机车队过渡到 2(3)ES5S 系列下一代电力机车进行经济评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信