Enhancing indoor air quality and sustainable living in newly constructed apartments: insights from Dubai

IF 2.2 Q2 CONSTRUCTION & BUILDING TECHNOLOGY
Chuloh Jung, Naglaa Sami Abdelaziz Mahmoud, Nahla Alqassimi
{"title":"Enhancing indoor air quality and sustainable living in newly constructed apartments: insights from Dubai","authors":"Chuloh Jung, Naglaa Sami Abdelaziz Mahmoud, Nahla Alqassimi","doi":"10.3389/fbuil.2023.1292531","DOIUrl":null,"url":null,"abstract":"This research paper examines Indoor Air Quality (IAQ) conditions in newly constructed apartments in Dubai to be more sustainable for residents to have healthier lifestyles. Enhanced airtightness and chemical-laden materials contribute to IAQ pollution in these buildings. The study aims to assess pollutant concentrations and variations based on building height. Measurements were conducted in 12 apartment units using the WHO’s IAQ assessment methodology. Most pollutants were within limits, but TVOC exceeded the Dubai Municipality’s standard, measuring at 2634.4 μg/m³, approximately nine times higher than the standard. HCHO (163.4 μg/m³) and toluene (551.4 μg/m³) were identified as significant pollutants with potential health effects. Analysis of pollutant concentrations based on building height revealed higher TVOC levels in upper areas, with 2,828 μg/m³ in the upper area compared to 2,443 μg/m³ in the lower area, indicating more severe indoor air pollution in Ethylbenzene and styrene also highest in upper areas, with ethylbenzene at 122 μg/m³ and styrene at 82 μg/m³ in the upper area, potentially due to elevated sources. Toluene and xylene concentrations were elevated in the middle area, with toluene at 574 μg/m³ and xylene at 321 μg/m³, likely influenced by materials and occupant activities. Benzene concentrations were consistent across all heights at 2.94 μg/m³, suggesting a common source. HCHO concentrations were relatively consistent but slightly higher in the middle and upper areas, with 171 μg/m³ in both, likely influenced by ventilation and emissions. While average pollutant concentrations met WHO standards, many units exceeded recommended limits, requiring targeted interventions. The study highlights the importance of addressing IAQ concerns and implementing strategies to reduce indoor air pollutants and improve ventilation. These findings contribute to IAQ knowledge in Dubai’s residential buildings, guiding policymakers, architects, and developers in effective policies and guidelines. Further research on seasonal variations and other IAQ factors is recommended for better understanding and long-term monitoring. Prioritizing IAQ in newly constructed apartments is crucial for healthier living in Dubai. The residential building sector can protect residents’ health by implementing appropriate measures while delivering upscale living experiences.","PeriodicalId":37112,"journal":{"name":"Frontiers in Built Environment","volume":"62 13","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fbuil.2023.1292531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This research paper examines Indoor Air Quality (IAQ) conditions in newly constructed apartments in Dubai to be more sustainable for residents to have healthier lifestyles. Enhanced airtightness and chemical-laden materials contribute to IAQ pollution in these buildings. The study aims to assess pollutant concentrations and variations based on building height. Measurements were conducted in 12 apartment units using the WHO’s IAQ assessment methodology. Most pollutants were within limits, but TVOC exceeded the Dubai Municipality’s standard, measuring at 2634.4 μg/m³, approximately nine times higher than the standard. HCHO (163.4 μg/m³) and toluene (551.4 μg/m³) were identified as significant pollutants with potential health effects. Analysis of pollutant concentrations based on building height revealed higher TVOC levels in upper areas, with 2,828 μg/m³ in the upper area compared to 2,443 μg/m³ in the lower area, indicating more severe indoor air pollution in Ethylbenzene and styrene also highest in upper areas, with ethylbenzene at 122 μg/m³ and styrene at 82 μg/m³ in the upper area, potentially due to elevated sources. Toluene and xylene concentrations were elevated in the middle area, with toluene at 574 μg/m³ and xylene at 321 μg/m³, likely influenced by materials and occupant activities. Benzene concentrations were consistent across all heights at 2.94 μg/m³, suggesting a common source. HCHO concentrations were relatively consistent but slightly higher in the middle and upper areas, with 171 μg/m³ in both, likely influenced by ventilation and emissions. While average pollutant concentrations met WHO standards, many units exceeded recommended limits, requiring targeted interventions. The study highlights the importance of addressing IAQ concerns and implementing strategies to reduce indoor air pollutants and improve ventilation. These findings contribute to IAQ knowledge in Dubai’s residential buildings, guiding policymakers, architects, and developers in effective policies and guidelines. Further research on seasonal variations and other IAQ factors is recommended for better understanding and long-term monitoring. Prioritizing IAQ in newly constructed apartments is crucial for healthier living in Dubai. The residential building sector can protect residents’ health by implementing appropriate measures while delivering upscale living experiences.
提高新建公寓的室内空气质量和可持续生活:迪拜的启示
本研究论文探讨了迪拜新建公寓的室内空气质量(IAQ)状况,目的是让居民拥有更健康的生活方式。增强的气密性和含化学物质的材料造成了这些建筑的室内空气质量污染。这项研究旨在评估污染物浓度以及根据建筑物高度而产生的变化。采用世界卫生组织的室内空气质量评估方法,对 12 个公寓单元进行了测量。大多数污染物都在限值范围内,但 TVOC 超过了迪拜市政府的标准,测量值为 2634.4 μg/m³,比标准高出约 9 倍。六氯环己烷(163.4 μg/m³)和甲苯(551.4 μg/m³)被确定为对健康有潜在影响的重要污染物。基于建筑高度的污染物浓度分析表明,上层区域的 TVOC 含量较高,上层区域为 2,828 μg/m³ ,而下层区域为 2,443 μg/m³,这表明乙苯和苯乙烯的室内空气污染在上层区域也最为严重,上层区域的乙苯浓度为 122 μg/m³,苯乙烯浓度为 82 μg/m³,这可能是由于污染源升高所致。中间区域的甲苯和二甲苯浓度较高,甲苯浓度为 574 μg/m³,二甲苯浓度为 321 μg/m³,这可能是受材料和居住者活动的影响。所有高度的苯浓度一致,均为 2.94 μg/m³,这表明存在一个共同的来源。六氯环己烷的浓度相对一致,但在中部和上部区域略高,均为 171 μg/m³,可能受到通风和排放的影响。虽然污染物的平均浓度符合世界卫生组织的标准,但许多单位都超过了建议限值,需要采取有针对性的干预措施。这项研究强调了解决室内空气质量问题以及实施减少室内空气污染物和改善通风策略的重要性。这些研究结果有助于了解迪拜住宅楼的室内空气质量,为决策者、建筑师和开发商制定有效的政策和指导方针提供指导。建议进一步研究季节变化和其他室内空气质量因素,以便更好地理解和长期监测。在新建公寓中优先考虑室内空气质量对迪拜的健康生活至关重要。住宅建筑部门可以通过实施适当的措施来保护居民的健康,同时提供高档的生活体验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Frontiers in Built Environment
Frontiers in Built Environment Social Sciences-Urban Studies
CiteScore
4.80
自引率
6.70%
发文量
266
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信