Shaping ability of a pediatric motor-driven instrumentation system in primary molar root canal prototypes.

Brazilian dental journal Pub Date : 2023-12-22 eCollection Date: 2023-01-01 DOI:10.1590/0103-6440202305372
Bianca Katsumata de Souza, Murilo Priori Alcalde, Marco Antonio Hungaro Duarte, Maria Aparecida Andrade Moreira Machado, Thais Marchini Oliveira, Natalino Lourenço Neto
{"title":"Shaping ability of a pediatric motor-driven instrumentation system in primary molar root canal prototypes.","authors":"Bianca Katsumata de Souza, Murilo Priori Alcalde, Marco Antonio Hungaro Duarte, Maria Aparecida Andrade Moreira Machado, Thais Marchini Oliveira, Natalino Lourenço Neto","doi":"10.1590/0103-6440202305372","DOIUrl":null,"url":null,"abstract":"<p><p>Evaluate the shaping ability and preparation time using a pediatric motor-driven rotary instrumentation compared to other systems in resin prototypes of primary molars.</p><p><strong>Methods: </strong>Thirty specimens were scanned in micro-CT and divided into three groups according to the instrumentation type: pediatric motor-driven Sequence baby File (SBF); conventional motor-driven (Sequence Rotary File - SRF); manual K file. Instrumentation time was timed. After preparation, the specimens were scanned again. The pre- and post-instrumentation images were superimposed to measure the amount of root canal deviation and the resin remnant thickness. ANOVA followed by the Tukey test analyzed the comparisons between groups (p<0.05).</p><p><strong>Results: </strong>No statistically significant differences occurred in root canal deviation among groups (p>0.05). There were statistically significant differences in the comparison among root thirds (p<0.001) but without significant differences in the interaction group vs. root third (p>0.05). Both motor-driven instrumentations showed statistically greater weariness than manual instrumentation (p<0.001), without significant significant differences between SBF and SRF. Motor-driven instrumentation had a shorter working time than manual instrumentation (p<0.001).</p><p><strong>Conclusion: </strong>Pediatric motor-driven instrumentation demonstrated good outcomes in relation to root canal deviation and amount of remnant structure, with shorter instrumentation time. SBF can be a suitable alternative for endodontic instrumentation in primary molars.</p>","PeriodicalId":101363,"journal":{"name":"Brazilian dental journal","volume":"34 5","pages":"36-42"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10759958/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202305372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Evaluate the shaping ability and preparation time using a pediatric motor-driven rotary instrumentation compared to other systems in resin prototypes of primary molars.

Methods: Thirty specimens were scanned in micro-CT and divided into three groups according to the instrumentation type: pediatric motor-driven Sequence baby File (SBF); conventional motor-driven (Sequence Rotary File - SRF); manual K file. Instrumentation time was timed. After preparation, the specimens were scanned again. The pre- and post-instrumentation images were superimposed to measure the amount of root canal deviation and the resin remnant thickness. ANOVA followed by the Tukey test analyzed the comparisons between groups (p<0.05).

Results: No statistically significant differences occurred in root canal deviation among groups (p>0.05). There were statistically significant differences in the comparison among root thirds (p<0.001) but without significant differences in the interaction group vs. root third (p>0.05). Both motor-driven instrumentations showed statistically greater weariness than manual instrumentation (p<0.001), without significant significant differences between SBF and SRF. Motor-driven instrumentation had a shorter working time than manual instrumentation (p<0.001).

Conclusion: Pediatric motor-driven instrumentation demonstrated good outcomes in relation to root canal deviation and amount of remnant structure, with shorter instrumentation time. SBF can be a suitable alternative for endodontic instrumentation in primary molars.

小儿电机驱动器械系统在初级磨牙根管原型中的塑形能力。
在初级磨牙树脂原型中,与其他系统相比,评估儿科马达驱动旋转器械的塑形能力和预备时间:用显微CT扫描了30个样本,并根据器械类型将其分为三组:小儿电机驱动序列婴儿锉(SBF);传统电机驱动(序列旋转锉-SRF);手动K锉。仪器操作时间是计时的。制备完成后,再次对标本进行扫描。将器械前和器械后的图像进行叠加,以测量根管偏差量和树脂残余厚度。方差分析和 Tukey 检验分析了组间比较(p 结果:各组间根管偏移量差异无统计学意义(P>0.05)。根三度之间的比较差异有统计学意义(P0.05)。从统计学角度看,两种电机驱动器械的磨损程度均高于手动器械(P结论:小儿电机驱动器械在根管偏离和残余结构量方面表现出良好的效果,而且器械操作时间更短。SBF 可以作为初级磨牙根管器械治疗的合适替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信