Long-term effect of firing protocols on surface roughness and flexural strength of lithium disilicate glass-ceramic.

Brazilian dental journal Pub Date : 2023-12-22 eCollection Date: 2023-01-01 DOI:10.1590/0103-6440202305496
Kaíssa da Cunha Lima, Rocio Geng Vivanco, Pedro Roberto Braz Rodrigues, Ana Lúcia Pereira Caetano, Fernanda de Carvalho Panzeri Pires-de-Souza
{"title":"Long-term effect of firing protocols on surface roughness and flexural strength of lithium disilicate glass-ceramic.","authors":"Kaíssa da Cunha Lima, Rocio Geng Vivanco, Pedro Roberto Braz Rodrigues, Ana Lúcia Pereira Caetano, Fernanda de Carvalho Panzeri Pires-de-Souza","doi":"10.1590/0103-6440202305496","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the effect of different firing protocols on the surface roughness and flexural strength of CAD/CAM lithium disilicate glass-ceramic (LD) after aging methods. Forty-two LD bars of 16 x 4 x 2 mm (IPS e-max CAD, Ivoclar) were randomly separated into two groups according to firing protocols: Single firing-Staining, glazing, and crystallization in a single step; Multiple firings-Crystallization+First staining+Firing+Second staining+Firing+Glazing+Firing. After protocols, initial surface roughness readings were taken (Surfcorder SE1700, Kosakalab). Samples were then randomly separated into three groups (n=7) according to the aging methods they were submitted: Thermomechanical cycling (TMC, ER System, Erios, 1,200,000 cycles, 0.3 MPa, 2 Hz and 5°C/37°C/55°C, 30 s swell time); Simulated toothbrushing (STB, Pepsodent, MAVTEC, 73,000 cycles), and Control (no aging). Final surface roughness readings were done, and samples were submitted to a three-point bending test (OM100, Odeme Dental Research) and fractographic analysis by scanning electron microscopy (EVO-MA10, ZEISS). Data were analyzed (2-way ANOVA, (α=.05). There was no difference (p>.05) in the flexural strength between the firing protocols, regardless of the aging method. STB decreased the flexural strength of samples submitted to multiple firings, different from control (p<.05). Without aging (Control), before TMC, and after STB, LD had lower surface roughness when submitted to multiple firings than to single firing (p<.05). The firing protocols did not affect the flexural strength or the surface roughness of the lithium disilicate glass-ceramic, even after aging. However, toothbrushing negatively affected the flexural strength and smoothed the surface of the ceramic submitted to multiple firings.</p>","PeriodicalId":101363,"journal":{"name":"Brazilian dental journal","volume":"34 5","pages":"79-86"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10759956/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202305496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the effect of different firing protocols on the surface roughness and flexural strength of CAD/CAM lithium disilicate glass-ceramic (LD) after aging methods. Forty-two LD bars of 16 x 4 x 2 mm (IPS e-max CAD, Ivoclar) were randomly separated into two groups according to firing protocols: Single firing-Staining, glazing, and crystallization in a single step; Multiple firings-Crystallization+First staining+Firing+Second staining+Firing+Glazing+Firing. After protocols, initial surface roughness readings were taken (Surfcorder SE1700, Kosakalab). Samples were then randomly separated into three groups (n=7) according to the aging methods they were submitted: Thermomechanical cycling (TMC, ER System, Erios, 1,200,000 cycles, 0.3 MPa, 2 Hz and 5°C/37°C/55°C, 30 s swell time); Simulated toothbrushing (STB, Pepsodent, MAVTEC, 73,000 cycles), and Control (no aging). Final surface roughness readings were done, and samples were submitted to a three-point bending test (OM100, Odeme Dental Research) and fractographic analysis by scanning electron microscopy (EVO-MA10, ZEISS). Data were analyzed (2-way ANOVA, (α=.05). There was no difference (p>.05) in the flexural strength between the firing protocols, regardless of the aging method. STB decreased the flexural strength of samples submitted to multiple firings, different from control (p<.05). Without aging (Control), before TMC, and after STB, LD had lower surface roughness when submitted to multiple firings than to single firing (p<.05). The firing protocols did not affect the flexural strength or the surface roughness of the lithium disilicate glass-ceramic, even after aging. However, toothbrushing negatively affected the flexural strength and smoothed the surface of the ceramic submitted to multiple firings.

烧制规程对二硅酸锂玻璃陶瓷表面粗糙度和抗弯强度的长期影响
本研究评估了不同烧制方案对 CAD/CAM 二硅酸锂玻璃陶瓷(LD)老化后的表面粗糙度和抗弯强度的影响。将 42 个 16 x 4 x 2 mm 的 LD 棒(IPS e-max CAD,Ivoclar 公司)按烧结方案随机分为两组:单次烧结--一次完成染色、上釉和结晶;多次烧结--结晶+第一次染色+烧结+第二次染色+烧结+上釉+烧结。协议完成后,测量初始表面粗糙度读数(Surfcorder SE1700,Kosakalab)。然后根据老化方法将样品随机分为三组(n=7):热机械循环(TMC,ER System,Erios,1,200,000 次循环,0.3 兆帕,2 赫兹,5°C/37°C/55°C,30 秒膨胀时间);模拟刷牙(STB,Pepsodent,MAVTEC,73,000 次循环)和对照组(无老化)。最后读取表面粗糙度,对样品进行三点弯曲测试(OM100,Odeme Dental Research),并用扫描电子显微镜(EVO-MA10,ZEISS)进行断裂分析。数据分析采用 2 方方差分析(α=.05)。无论采用哪种老化方法,焙烧方案之间的抗折强度均无差异(p>.05)。STB 降低了经过多次焙烧的样品的抗弯强度,与对照组不同(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信