Fluoride-modified implant surfaces improves osseointegration in the tibias of rats with induced diabetes.

Brazilian dental journal Pub Date : 2023-12-22 eCollection Date: 2023-01-01 DOI:10.1590/0103-6440202305439
Guilherme José Pimentel Lopes de Oliveira, Lucas Amaral Fontanari, João Antônio Chaves de Souza, Rubens Spin-Neto, Carlos Nelson Elias, Elcio Marcantonio Junior, Silvana Regina Perez Orrico
{"title":"Fluoride-modified implant surfaces improves osseointegration in the tibias of rats with induced diabetes.","authors":"Guilherme José Pimentel Lopes de Oliveira, Lucas Amaral Fontanari, João Antônio Chaves de Souza, Rubens Spin-Neto, Carlos Nelson Elias, Elcio Marcantonio Junior, Silvana Regina Perez Orrico","doi":"10.1590/0103-6440202305439","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.</p>","PeriodicalId":101363,"journal":{"name":"Brazilian dental journal","volume":"34 5","pages":"43-52"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10759961/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202305439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the influence of a fluoride-modified titanium surface on osseointegration in rats with induced diabetes. One hundred and eighty rats were randomly allocated into 3 groups with 60 animals each: Control group (C): Animals without diabetes; Diabetes Group (D): Animals with uncontrolled induced diabetes; Controlled Diabetes Group (CD): Animals with diabetes induced controlled by the insulin administration. Diabetes was induced by streptozotocin injection. Each animal received 2 implants in the proximal tibial metaphysis, one with the machined surface (M) and the other one with a fluoride-modified titanium surface (F), after 4 weeks of induction of diabetes. The animals were submitted to euthanasia 2, 4, and 6 weeks after the implant placement (n = 20 animals/group). The osseointegration was evaluated by the implant removal torque test and the histometric analysis of the non-decalcified histological sections: 1) Contact bone/implant (%BIC); 2) Bone tissue area between implant threads (%BBT). Implants with F surface showed a higher removal torque than implants with surface M in all groups. There was no difference in %BIC between the groups regardless of the surface used. The F surface showed a tendency to present higher %BBT values for the 3 evaluation periods in the D group. The fluoride-modified implant surface has no impact on the %BIC and %BBT. However, the fluoride-modified implant surface increases the locking of the implants with the bone. The hyperglycemia was associated with lower removal torque values despite the surfaces of the implant used.

氟改性种植体表面可改善糖尿病大鼠胫骨的骨结合。
本研究评估了氟改性钛表面对糖尿病大鼠骨结合的影响。180 只大鼠随机分为 3 组,每组 60 只:对照组(C):对照组(C):无糖尿病动物;糖尿病组(D):未控制的诱发糖尿病动物;控制糖尿病组(CD):通过注射胰岛素控制糖尿病的动物。通过注射链脲佐菌素诱发糖尿病。糖尿病诱导 4 周后,每只动物在胫骨近端干骺端接受 2 个植入物,一个是机加工表面(M),另一个是氟化改性钛表面(F)。动物在植入假体 2、4 和 6 周后安乐死(n = 20 只/组)。通过种植体拔除扭矩测试和未脱钙组织切片的组织计量分析来评估骨结合情况:1)接触骨/种植体(%BIC);2)种植体螺纹间的骨组织面积(%BBT)。在所有组别中,表面为 F 的种植体比表面为 M 的种植体具有更高的拔除扭矩。无论使用哪种表面,各组之间的 BIC%均无差异。在 D 组的 3 个评估期中,F 表面的 %BBT 值呈上升趋势。氟改性种植体表面对%BIC和%BBT没有影响。不过,氟改性种植体表面增加了种植体与骨的锁定性。尽管使用了不同的种植体表面,但高血糖与较低的拔除扭矩值有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信