Rodrigo Ribeiro E Silva, Vinicius Ribas de Abreu Borges, Alexandre Grunfeld Starling Jardim, Maria Luisa Hostin Volpi, Leonora Zozula Blind Pope, Manuella Zattar Medeiros
{"title":"Correlation between thyroid fine needle aspiration and pathological examination: a 10 year retrospective study.","authors":"Rodrigo Ribeiro E Silva, Vinicius Ribas de Abreu Borges, Alexandre Grunfeld Starling Jardim, Maria Luisa Hostin Volpi, Leonora Zozula Blind Pope, Manuella Zattar Medeiros","doi":"10.31744/einstein_journal/2023AO0418","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To establish the diagnostic performance of fine-needle aspiration in detecting benign and malignant neoplasm in comparison with post-thyroidectomy histopathological findings among patients who received a thyroidectomy.</p><p><strong>Methods: </strong>Retrospective observational data collected between 2011-2021 were included from patients who received partial or total thyroidectomy. The Bethesda system was used to classify neoplasms from fine-needle aspiration procedures as benign or malignant. Sample characteristics, diagnostic accuracy, sensitivity, specificity, and predictive values were evaluated.</p><p><strong>Results: </strong>Patients (n=360) who underwent thyroidectomy were analyzed, of whom 142 (39.4%) and 218 (60.6%) had benign and malignant neoplasms, respectively. Using the Bethesda system, 23 (6.4%) were classified as unsatisfactory result (BI), 83 (23.1%) as benign (BII), 50 (13.9%) as atypia of undetermined significance (BIII), 23 (6.4%) as suspected follicular or Hürthle cell neoplasia (BIV), 102 (28.3%) as suspected malignancy (BV) and 79 (21.9%) as malignant (BVI). The fine-needle aspiration diagnostic accuracy for carcinomas was 92%, while the sensitivity and specificity were 94.4% and 86.9%, respectively. The negative and positive predictive values were 87.9% and 93.9%, respectively.</p><p><strong>Conclusion: </strong>Fine-needle aspiration has high diagnostic accuracy, sensitivity and specificity, and is a reliable test for distinguishing between benign and malignant thyroid pathologies.</p>","PeriodicalId":47359,"journal":{"name":"Einstein-Sao Paulo","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10730258/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Einstein-Sao Paulo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31744/einstein_journal/2023AO0418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To establish the diagnostic performance of fine-needle aspiration in detecting benign and malignant neoplasm in comparison with post-thyroidectomy histopathological findings among patients who received a thyroidectomy.
Methods: Retrospective observational data collected between 2011-2021 were included from patients who received partial or total thyroidectomy. The Bethesda system was used to classify neoplasms from fine-needle aspiration procedures as benign or malignant. Sample characteristics, diagnostic accuracy, sensitivity, specificity, and predictive values were evaluated.
Results: Patients (n=360) who underwent thyroidectomy were analyzed, of whom 142 (39.4%) and 218 (60.6%) had benign and malignant neoplasms, respectively. Using the Bethesda system, 23 (6.4%) were classified as unsatisfactory result (BI), 83 (23.1%) as benign (BII), 50 (13.9%) as atypia of undetermined significance (BIII), 23 (6.4%) as suspected follicular or Hürthle cell neoplasia (BIV), 102 (28.3%) as suspected malignancy (BV) and 79 (21.9%) as malignant (BVI). The fine-needle aspiration diagnostic accuracy for carcinomas was 92%, while the sensitivity and specificity were 94.4% and 86.9%, respectively. The negative and positive predictive values were 87.9% and 93.9%, respectively.
Conclusion: Fine-needle aspiration has high diagnostic accuracy, sensitivity and specificity, and is a reliable test for distinguishing between benign and malignant thyroid pathologies.