Samuel Bert Boadi-Kusi , Princess Marie Aikins , Ebenezer Zaabaar , Anthony Gyimah Duku
{"title":"Visual function correlates of self-reported vision-related nighttime driving difficulties","authors":"Samuel Bert Boadi-Kusi , Princess Marie Aikins , Ebenezer Zaabaar , Anthony Gyimah Duku","doi":"10.1016/j.optom.2023.100506","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To investigate the visual function correlates of self-reported vision-related night driving difficulties among drivers.</p></div><div><h3>Methods</h3><p>One hundred and seven drivers (age: 46.06 ± 8.24, visual acuity [VA] of 0.2logMAR or better) were included in the study. A standard vision and night driving questionnaire (VND-Q) was administered. VA and contrast sensitivity were measured under photopic and mesopic conditions. Mesopic VA was remeasured after introducing a peripheral glare source into the participants' field of view to enable computation of disability glare index. Regression analyses were used to assess the associations between VND-Q scores, and visual function measures.</p></div><div><h3>Results</h3><p>The mean VND-Q score was -3.96±1.95 logit (interval scale score: 2.46±1.28). Simple linear regression models for photopic contrast sensitivity, mesopic VA, mesopic contrast sensitivity, and disability index significantly predicted VND-Q score (<em>P</em><0.05), with mesopic VA and disability glare index accounting for the greatest variation (21 %) in VND-Q scores followed by photopic contrast sensitivity (19 %), and mesopic contrast sensitivity (15 %). A multiple regression model to determine the association between the predictors (photopic contrast sensitivity, mesopic VA, mesopic contrast sensitivity, and disability index) and VND-Q score yielded significant results, F (4, 102) = 8.58, <em>P</em> < 0.001, <em>adj. R<sup>2</sup></em> = 0.2224. Seeing dark-colored cars was the most challenging vision task.</p></div><div><h3>Conclusion</h3><p>Changes in mesopic visual acuity, photopic and mesopic contrast sensitivity, as well as disability glare index are associated with and explain night driving-related visual difficulties. It is recommended to incorporate measurement of these visual functions into assessments related to driving performance.</p></div>","PeriodicalId":46407,"journal":{"name":"Journal of Optometry","volume":"17 3","pages":"Article 100506"},"PeriodicalIF":2.2000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1888429623000547/pdfft?md5=8abb525f488bea61def96da142d2a29f&pid=1-s2.0-S1888429623000547-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Optometry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1888429623000547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To investigate the visual function correlates of self-reported vision-related night driving difficulties among drivers.
Methods
One hundred and seven drivers (age: 46.06 ± 8.24, visual acuity [VA] of 0.2logMAR or better) were included in the study. A standard vision and night driving questionnaire (VND-Q) was administered. VA and contrast sensitivity were measured under photopic and mesopic conditions. Mesopic VA was remeasured after introducing a peripheral glare source into the participants' field of view to enable computation of disability glare index. Regression analyses were used to assess the associations between VND-Q scores, and visual function measures.
Results
The mean VND-Q score was -3.96±1.95 logit (interval scale score: 2.46±1.28). Simple linear regression models for photopic contrast sensitivity, mesopic VA, mesopic contrast sensitivity, and disability index significantly predicted VND-Q score (P<0.05), with mesopic VA and disability glare index accounting for the greatest variation (21 %) in VND-Q scores followed by photopic contrast sensitivity (19 %), and mesopic contrast sensitivity (15 %). A multiple regression model to determine the association between the predictors (photopic contrast sensitivity, mesopic VA, mesopic contrast sensitivity, and disability index) and VND-Q score yielded significant results, F (4, 102) = 8.58, P < 0.001, adj. R2 = 0.2224. Seeing dark-colored cars was the most challenging vision task.
Conclusion
Changes in mesopic visual acuity, photopic and mesopic contrast sensitivity, as well as disability glare index are associated with and explain night driving-related visual difficulties. It is recommended to incorporate measurement of these visual functions into assessments related to driving performance.