Extended Sanitation Intervals for Cage Components and Automated Watering Valves: Validation and Cost Analysis.

Bryanna Meredith, Bridget M Clancy, Allison Ostdiek, George P Langan, Kerith R Luchins
{"title":"Extended Sanitation Intervals for Cage Components and Automated Watering Valves: Validation and Cost Analysis.","authors":"Bryanna Meredith, Bridget M Clancy, Allison Ostdiek, George P Langan, Kerith R Luchins","doi":"10.30802/AALAS-JAALAS-23-000084","DOIUrl":null,"url":null,"abstract":"<p><p>Although the <i>Guide</i> suggests changing rodent cage components every 2 wk, it states that \"decreased sanitation frequency may be justified if the microenvironment in the cages, under the condition of use ..., is not compromised.\" The purpose of this study was to evaluate extended sanitation intervals of cage components (automated watering valve, wire bar lid, and filter top) of mouse individually ventilated caging (IVCs) at our institution. We hypothesized that there would be no significant difference in relative light units measured by ATP luminometry of these cage components at the control time point of 14 d as compared with each extended time interval: 28, 56, and 84 d. In addition, for automated watering valves, the study was extended to 168 d. We also hypothesized that time-and-motion studies performed by moving to a sanitation interval of 84 d for all components would result in substantial time and cost savings. The components of a total of 24 cages containing 4 or 5 mice each were swabbed, and an ATP luminometer was used to detect organic matter. We found no significant differences in organic matter load between 14 d and all other time points for all cage components. Our time- and cost-savings analysis found that extending the sanitation interval of cage components from every 2 wk (14 d) to every 3 mo (84 d) for every 10,000 cages would save about 3,000 technician hours annually, for a total annual labor cost savings of about $100,000. This study is the first to validate the extended sanitation interval of automated watering valves and confirms the findings of previous studies that validated the extended sanitation frequency of wire bar lids and filter tops of rodent IVCs. Overall, extending the sanitation frequency of cage components reduces workload of animal care staff without compromising the cage microenvironment.</p>","PeriodicalId":94111,"journal":{"name":"Journal of the American Association for Laboratory Animal Science : JAALAS","volume":" ","pages":"34-40"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10844734/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Association for Laboratory Animal Science : JAALAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30802/AALAS-JAALAS-23-000084","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/9 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Although the Guide suggests changing rodent cage components every 2 wk, it states that "decreased sanitation frequency may be justified if the microenvironment in the cages, under the condition of use ..., is not compromised." The purpose of this study was to evaluate extended sanitation intervals of cage components (automated watering valve, wire bar lid, and filter top) of mouse individually ventilated caging (IVCs) at our institution. We hypothesized that there would be no significant difference in relative light units measured by ATP luminometry of these cage components at the control time point of 14 d as compared with each extended time interval: 28, 56, and 84 d. In addition, for automated watering valves, the study was extended to 168 d. We also hypothesized that time-and-motion studies performed by moving to a sanitation interval of 84 d for all components would result in substantial time and cost savings. The components of a total of 24 cages containing 4 or 5 mice each were swabbed, and an ATP luminometer was used to detect organic matter. We found no significant differences in organic matter load between 14 d and all other time points for all cage components. Our time- and cost-savings analysis found that extending the sanitation interval of cage components from every 2 wk (14 d) to every 3 mo (84 d) for every 10,000 cages would save about 3,000 technician hours annually, for a total annual labor cost savings of about $100,000. This study is the first to validate the extended sanitation interval of automated watering valves and confirms the findings of previous studies that validated the extended sanitation frequency of wire bar lids and filter tops of rodent IVCs. Overall, extending the sanitation frequency of cage components reduces workload of animal care staff without compromising the cage microenvironment.

延长笼舍部件和自动浇水阀的卫生间隔:验证和成本分析。
尽管《指南》建议每 2 周更换一次啮齿动物笼子部件,但它指出 "如果笼子中的微环境在使用条件下......没有受到破坏,则可以适当降低消毒频率"。本研究的目的是评估本机构对小鼠独立通风饲养笼(IVC)的笼子部件(自动饮水阀、线棒盖和过滤器顶盖)延长消毒间隔的情况。我们假设,在 14 天的对照时间点与 28、56 和 84 天的延长时间间隔相比,用 ATP 发光测定法测量笼子部件的相对光单位没有显著差异。我们对总共 24 个笼子(每个笼子装有 4 或 5 只小鼠)的各部分进行了拭抹,并使用 ATP 发光器检测有机物。我们发现,在 14 天和所有其他时间点之间,所有笼子部件的有机物含量均无明显差异。我们的时间和成本节约分析发现,每 10,000 个笼子的笼子部件的卫生间隔从每 2 周(14 d)延长到每 3 个月(84 d),每年可节省约 3,000 个技术人员工时,每年可节省约 100,000 美元的劳动力成本。这项研究首次验证了延长自动浇水阀的卫生间隔时间,并证实了之前验证延长啮齿动物 IVC 的铁丝网盖和过滤器顶部卫生频率的研究结果。总之,延长笼子部件的消毒频率可以减少动物护理人员的工作量,同时又不会影响笼子的微环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信