Initial stability of cementless acetabular cups using robotic-assisted total hip arthroplasty compared with the conventional manual technique: An in vitro biomechanical study

IF 2.3 3区 医学 Q2 SURGERY
Ryo Hidaka, Kenta Matsuda, Hidetaka Mochizuki, Hirotaka Kawano
{"title":"Initial stability of cementless acetabular cups using robotic-assisted total hip arthroplasty compared with the conventional manual technique: An in vitro biomechanical study","authors":"Ryo Hidaka,&nbsp;Kenta Matsuda,&nbsp;Hidetaka Mochizuki,&nbsp;Hirotaka Kawano","doi":"10.1002/rcs.2613","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The aim of this study is to determine whether the initial stability of a cementless cup with the Mako system is superior to that of a conventional manual technique using bone models.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The bone models were prepared using a polyurethane foam block. Two hemispherical cementless cups (highly porous titanium cup [Trident II Tritanium, Stryker] and hydroxyapatite-coated titanium cup [Trident HA, Stryker]) were implanted using the Mako system. The torque of the cups was measured by rotational and lever-out torque testing and compared with that of a conventional manual technique.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The two types of cups that were implanted using the Mako system demonstrated significantly higher mean rotational torque than that of the manual technique (<i>p</i> &lt; 0.01, <i>p</i> = 0.01, respectively).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>This study provides the advantage of the initial stability of a cementless hemispherical cup implanted by the Mako system compared with that of the conventional manual technique.</p>\n </section>\n </div>","PeriodicalId":50311,"journal":{"name":"International Journal of Medical Robotics and Computer Assisted Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Robotics and Computer Assisted Surgery","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2613","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The aim of this study is to determine whether the initial stability of a cementless cup with the Mako system is superior to that of a conventional manual technique using bone models.

Methods

The bone models were prepared using a polyurethane foam block. Two hemispherical cementless cups (highly porous titanium cup [Trident II Tritanium, Stryker] and hydroxyapatite-coated titanium cup [Trident HA, Stryker]) were implanted using the Mako system. The torque of the cups was measured by rotational and lever-out torque testing and compared with that of a conventional manual technique.

Results

The two types of cups that were implanted using the Mako system demonstrated significantly higher mean rotational torque than that of the manual technique (p < 0.01, p = 0.01, respectively).

Conclusions

This study provides the advantage of the initial stability of a cementless hemispherical cup implanted by the Mako system compared with that of the conventional manual technique.

使用机器人辅助全髋关节成形术与传统人工技术相比,无骨水泥髋臼杯的初始稳定性:体外生物力学研究
本研究的目的是利用骨模型确定使用 Mako 系统的无骨水泥髋臼杯的初始稳定性是否优于传统的手动技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.50
自引率
12.00%
发文量
131
审稿时长
6-12 weeks
期刊介绍: The International Journal of Medical Robotics and Computer Assisted Surgery provides a cross-disciplinary platform for presenting the latest developments in robotics and computer assisted technologies for medical applications. The journal publishes cutting-edge papers and expert reviews, complemented by commentaries, correspondence and conference highlights that stimulate discussion and exchange of ideas. Areas of interest include robotic surgery aids and systems, operative planning tools, medical imaging and visualisation, simulation and navigation, virtual reality, intuitive command and control systems, haptics and sensor technologies. In addition to research and surgical planning studies, the journal welcomes papers detailing clinical trials and applications of computer-assisted workflows and robotic systems in neurosurgery, urology, paediatric, orthopaedic, craniofacial, cardiovascular, thoraco-abdominal, musculoskeletal and visceral surgery. Articles providing critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies, commenting on ease of use, or addressing surgical education and training issues are also encouraged. The journal aims to foster a community that encompasses medical practitioners, researchers, and engineers and computer scientists developing robotic systems and computational tools in academic and commercial environments, with the intention of promoting and developing these exciting areas of medical technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信