3D PRINTED COMPUTER GUIDED Vs CONVENTIAL ARTHROCENTESIS IN THE MANAGEMENT OF TEMPOROMANDIBULAR JOINT INTERNAL DERANGEMENT

Ahmed Fahmy, Nevien Mohamed, Gaafar El Halawani
{"title":"3D PRINTED COMPUTER GUIDED Vs CONVENTIAL ARTHROCENTESIS IN THE MANAGEMENT OF TEMPOROMANDIBULAR JOINT INTERNAL DERANGEMENT","authors":"Ahmed Fahmy, Nevien Mohamed, Gaafar El Halawani","doi":"10.21608/adjalexu.2022.166907.1319","DOIUrl":null,"url":null,"abstract":"INTRODUCTION: Temporomandibular disorder (TMD) is a general term that comprises a wide range of clinical problems involving orofacial muscles and joints with the help of patient specific guide we do arthrocentesis as a non-invasive treatment. OBJECTIVE: The aim of this study was to evaluate the efficiency of 3D printed patient customized guides in conjugation with arthrocentesis in treatment of internal derangement of temporomandibular joint followed by PRP injection. MATERIALS AND METHODS: A total of 20 patients were divided into two groups. In group I patients with internal derangement were managed with patient specific guide to perform arthrocentesis in comparison with the conventional technique that was used in group II. The pain intensity, maximum inter-incisal opening and range of jaw movement in lateral and protrusion movement, joint noise, number of needle relocation and duration of the procedure were assessed. RESULTS: No needle relocation was required in the study group in contrast to the control group, with a statistically significant difference (p=0.030). The difference in the operation duration between both groups was statistically significant(p=0.003), with the study group requiring shorter time to conduct the procedure. A statistically insignificant difference was reported regarding the pain intensity, disturbance in jaw function, maximum inter-incisal opening, range in jaw movement, and joint noise. CONCLUSION: It may be concluded from the results of this study that a computer guided patient specific arthrocentesis guide based on a preoperative CT-scan is a reliable and reproducible method for accurate and more robust conduction of the arthrocentesis procedure with minimal modifications and low complication rate.","PeriodicalId":7723,"journal":{"name":"Alexandria Dental Journal","volume":" 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Alexandria Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjalexu.2022.166907.1319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

INTRODUCTION: Temporomandibular disorder (TMD) is a general term that comprises a wide range of clinical problems involving orofacial muscles and joints with the help of patient specific guide we do arthrocentesis as a non-invasive treatment. OBJECTIVE: The aim of this study was to evaluate the efficiency of 3D printed patient customized guides in conjugation with arthrocentesis in treatment of internal derangement of temporomandibular joint followed by PRP injection. MATERIALS AND METHODS: A total of 20 patients were divided into two groups. In group I patients with internal derangement were managed with patient specific guide to perform arthrocentesis in comparison with the conventional technique that was used in group II. The pain intensity, maximum inter-incisal opening and range of jaw movement in lateral and protrusion movement, joint noise, number of needle relocation and duration of the procedure were assessed. RESULTS: No needle relocation was required in the study group in contrast to the control group, with a statistically significant difference (p=0.030). The difference in the operation duration between both groups was statistically significant(p=0.003), with the study group requiring shorter time to conduct the procedure. A statistically insignificant difference was reported regarding the pain intensity, disturbance in jaw function, maximum inter-incisal opening, range in jaw movement, and joint noise. CONCLUSION: It may be concluded from the results of this study that a computer guided patient specific arthrocentesis guide based on a preoperative CT-scan is a reliable and reproducible method for accurate and more robust conduction of the arthrocentesis procedure with minimal modifications and low complication rate.
3D 打印计算机引导下的假关节切除术在治疗创伤性关节内部切除术中的应用
简介:颞下颌紊乱(TMD)是一个总称,包括广泛的涉及口面部肌肉和关节的临床问题,在患者特定指导下,我们将关节穿刺作为一种非侵入性治疗。目的:本研究旨在评价3D打印患者定制导向器结合关节穿刺治疗颞下颌关节内乱后PRP注射的效果。材料与方法:将20例患者分为两组。在I组中,与II组中使用的常规技术相比,有内部紊乱的患者在患者特定指导下进行关节穿刺。评估疼痛强度、最大切间开口和下颌侧向和前突运动范围、关节噪声、针移位次数和手术持续时间。结果:与对照组相比,研究组无需重新定位针头,差异有统计学意义(p=0.030)。两组手术时间差异有统计学意义(p=0.003),研究组手术时间更短。在疼痛强度、下颌功能障碍、最大切间开口、下颌活动范围和关节噪声方面,统计差异不显著。结论:从本研究的结果可以得出结论,基于术前ct扫描的计算机引导患者特异性关节穿刺指南是一种可靠、可重复的方法,可以准确、更稳健地引导关节穿刺过程,修改最少,并发症发生率低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信