{"title":"The Effect of a Compression Bandage on Dual Energy X-ray Absorptiometry Body Composition Scores","authors":"Yamileth Chacón-Araya , Elizabeth Carpio-Rivera , Andrea Quirós-Quirós , José Moncada-Jiménez","doi":"10.1016/j.jocd.2023.101461","DOIUrl":null,"url":null,"abstract":"<div><p><em>Background</em>: Dual-energy X-ray absorptiometry (DXA) measures are affected by the noise produced by external factors such as textile compression found in loose clothing. The study aimed to determine the effect of a compression bandage (CB) on body composition (BC) assessed by DXA.</p><p><em>Methods</em><span>: Sixty volunteers (age=21.4±4.7yr.) underwent full-body DXA scans on a control (CTRL) condition and after wearing a 30-mmHg CB on the trunk, legs, and arms. ANOVA (2 genders by 2 experimental conditions) determined mean interactions in BC variables tissue body fat% (BF%), region body fat% (RBF%), body tissue (BT), fat mass (FM), lean mass (LM), bone mineral content (BMC), and total mass (TM). Absolute reliability in BC scores was studied by the typical error of the measurement (TEM), the coefficient of variability (CV), and Bland-Altman plots.</span></p><p><em>Results</em>: ANOVA interactions were found on tissue total BF% (p=0.049), RBF% (p=0.048), android lean mass (p=0.004), and android total mass (p=0.019). The CV was small for tissue BF% (2.61±0.93%, CI95%=0.79, 4.43%), RBF% (2.66±1.78%, CI95%=-0.83, 6.15%), BT (4.82±2.19%, CI95%=0.54, 9.10kg), FM (4.17±2.25%, CI95%=-0.24, 8.58kg), LM (3.25±2.44%, CI95%=-1.53, 8.04kg), BMC (4.81±2.96%, CI95%=-0.99, 10.62kg), and TM (2.84±2.80%, CI95%=-2.65, 8.33kg). Bland-Altman plots showed random error for BF%, LM, and BMC. A bias of 0.5% was observed on BF% in males.</p><p><em>Conclusion</em>: A CB worn during a full-body DXA scan elicited similar BC scores than not wearing it. The variation in scores was <10% for most BC variables, and a trivial bias of 0.5% in BF% was detected in male scores.</p></div>","PeriodicalId":50240,"journal":{"name":"Journal of Clinical Densitometry","volume":"27 1","pages":"Article 101461"},"PeriodicalIF":1.7000,"publicationDate":"2023-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Densitometry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1094695023001117","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Dual-energy X-ray absorptiometry (DXA) measures are affected by the noise produced by external factors such as textile compression found in loose clothing. The study aimed to determine the effect of a compression bandage (CB) on body composition (BC) assessed by DXA.
Methods: Sixty volunteers (age=21.4±4.7yr.) underwent full-body DXA scans on a control (CTRL) condition and after wearing a 30-mmHg CB on the trunk, legs, and arms. ANOVA (2 genders by 2 experimental conditions) determined mean interactions in BC variables tissue body fat% (BF%), region body fat% (RBF%), body tissue (BT), fat mass (FM), lean mass (LM), bone mineral content (BMC), and total mass (TM). Absolute reliability in BC scores was studied by the typical error of the measurement (TEM), the coefficient of variability (CV), and Bland-Altman plots.
Results: ANOVA interactions were found on tissue total BF% (p=0.049), RBF% (p=0.048), android lean mass (p=0.004), and android total mass (p=0.019). The CV was small for tissue BF% (2.61±0.93%, CI95%=0.79, 4.43%), RBF% (2.66±1.78%, CI95%=-0.83, 6.15%), BT (4.82±2.19%, CI95%=0.54, 9.10kg), FM (4.17±2.25%, CI95%=-0.24, 8.58kg), LM (3.25±2.44%, CI95%=-1.53, 8.04kg), BMC (4.81±2.96%, CI95%=-0.99, 10.62kg), and TM (2.84±2.80%, CI95%=-2.65, 8.33kg). Bland-Altman plots showed random error for BF%, LM, and BMC. A bias of 0.5% was observed on BF% in males.
Conclusion: A CB worn during a full-body DXA scan elicited similar BC scores than not wearing it. The variation in scores was <10% for most BC variables, and a trivial bias of 0.5% in BF% was detected in male scores.
期刊介绍:
The Journal is committed to serving ISCD''s mission - the education of heterogenous physician specialties and technologists who are involved in the clinical assessment of skeletal health. The focus of JCD is bone mass measurement, including epidemiology of bone mass, how drugs and diseases alter bone mass, new techniques and quality assurance in bone mass imaging technologies, and bone mass health/economics.
Combining high quality research and review articles with sound, practice-oriented advice, JCD meets the diverse diagnostic and management needs of radiologists, endocrinologists, nephrologists, rheumatologists, gynecologists, family physicians, internists, and technologists whose patients require diagnostic clinical densitometry for therapeutic management.