Variations in the Urinary Iodine Concentration and Urinary Iodine/Creatinine Ratio among Preschool Children

IF 2.3 4区 医学 Q3 ENDOCRINOLOGY & METABOLISM
Dong An, Rui Yang, Yuping Du, Xuan Wang, Ying Yang, Wenxing Guo, Junhong Yang, Dongmei Meng, Weiwei Gao, Jiayi Zhang, Wen Chen, Wanqi Zhang
{"title":"Variations in the Urinary Iodine Concentration and Urinary Iodine/Creatinine Ratio among Preschool Children","authors":"Dong An, Rui Yang, Yuping Du, Xuan Wang, Ying Yang, Wenxing Guo, Junhong Yang, Dongmei Meng, Weiwei Gao, Jiayi Zhang, Wen Chen, Wanqi Zhang","doi":"10.1155/2023/6779094","DOIUrl":null,"url":null,"abstract":"Variations in different urinary measurements for evaluating iodine status are concerning to clinicians and researchers. The present study aimed to analyze the interindividual and intraindividual variations in the urinary iodine concentration (UIC) and urinary iodine/creatinine (UI/Cr) ratio and evaluate their application in assessing the iodine nutrition of preschool children. Four repeated spot urine samples were collected from 163 children at different times within one day. The urinary iodine concentration (UIC) and urinary creatinine concentration (UCr) were measured, and the UI/Cr ratio was calculated. The UIC (<svg height=\"8.68572pt\" style=\"vertical-align:-0.0498209pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 8.15071 8.68572\" width=\"8.15071pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"></path></g></svg> &lt; 0.001) and urinary iodine/creatinine ratio (<svg height=\"8.68572pt\" style=\"vertical-align:-0.0498209pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 8.15071 8.68572\" width=\"8.15071pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"><use xlink:href=\"#g113-81\"></use></g></svg> = 0.019) of multiple measurements were significantly different. The UIC of morning urine was highest (99.83 <i>μ</i>g/L) and then gradually decreased with collection time (<svg height=\"8.68572pt\" style=\"vertical-align:-0.0498209pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 8.15071 8.68572\" width=\"8.15071pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"><use xlink:href=\"#g113-81\"></use></g></svg> &lt; 0.001). In contrast, the UI/Cr ratio of morning urine samples increased with collection time. By computing the mean intraindividual and interindividual coefficients of variance (CV), the intraindividual variation of the UI/Cr ratio (68%) was significantly lower than that of the UIC (86%). Nevertheless, the interindividual variation was lowest in the UIC (78.62%) of morning urine. In addition, the UIC and UI/Cr ratio showed moderate correlations (<i>r</i> = 0.52, <svg height=\"8.68572pt\" style=\"vertical-align:-0.0498209pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 8.15071 8.68572\" width=\"8.15071pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"><use xlink:href=\"#g113-81\"></use></g></svg> &lt; 0.001), with kappa values of 0.42 in assessing iodine nutrition. The UIC of morning urine samples taken at 8:00–10:00 am was perhaps more stable and reliable in evaluating the iodine nutrition of preschool children at the population level. The UI/Cr ratio showed lower intraindividual variation and may be more suitable for assessing individual iodine nutrition.","PeriodicalId":13966,"journal":{"name":"International Journal of Endocrinology","volume":"12 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2023-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Endocrinology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/6779094","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Variations in different urinary measurements for evaluating iodine status are concerning to clinicians and researchers. The present study aimed to analyze the interindividual and intraindividual variations in the urinary iodine concentration (UIC) and urinary iodine/creatinine (UI/Cr) ratio and evaluate their application in assessing the iodine nutrition of preschool children. Four repeated spot urine samples were collected from 163 children at different times within one day. The urinary iodine concentration (UIC) and urinary creatinine concentration (UCr) were measured, and the UI/Cr ratio was calculated. The UIC ( < 0.001) and urinary iodine/creatinine ratio ( = 0.019) of multiple measurements were significantly different. The UIC of morning urine was highest (99.83 μg/L) and then gradually decreased with collection time ( < 0.001). In contrast, the UI/Cr ratio of morning urine samples increased with collection time. By computing the mean intraindividual and interindividual coefficients of variance (CV), the intraindividual variation of the UI/Cr ratio (68%) was significantly lower than that of the UIC (86%). Nevertheless, the interindividual variation was lowest in the UIC (78.62%) of morning urine. In addition, the UIC and UI/Cr ratio showed moderate correlations (r = 0.52,  < 0.001), with kappa values of 0.42 in assessing iodine nutrition. The UIC of morning urine samples taken at 8:00–10:00 am was perhaps more stable and reliable in evaluating the iodine nutrition of preschool children at the population level. The UI/Cr ratio showed lower intraindividual variation and may be more suitable for assessing individual iodine nutrition.
学龄前儿童尿碘浓度及尿碘/肌酐比值的变化
临床医生和研究人员对评估碘状态的不同尿液测量方法的差异感到担忧。本研究旨在分析学龄前儿童尿碘浓度(UIC)和尿碘/肌酐(UI/Cr)比值的个体间和个体内变化,并评价其在评估儿童碘营养中的应用价值。在一天内的不同时间对163名儿童收集了4个重复的尿样。测定尿碘浓度(UIC)和尿肌酐浓度(UCr),计算UI/Cr比值。多种测量的UIC (< 0.001)和尿碘/肌酐比(= 0.019)差异有统计学意义。晨尿UIC最高(99.83 μg/L),随收集时间的延长逐渐降低(< 0.001)。晨尿的UI/Cr随采集时间的延长而增加。通过计算个体内和个体间平均变异系数(CV), UI/Cr比值(68%)的个体内变异显著低于UIC(86%)。然而,个体间差异最低的是晨尿UIC(78.62%)。此外,UIC和UI/Cr比值呈中等相关性(r = 0.52, < 0.001), kappa值为0.42。8:00-10:00晨尿UIC在人群水平上评价学龄前儿童碘营养状况可能更为稳定可靠。UI/Cr的个体差异较小,可能更适合于评价个体碘营养状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Endocrinology
International Journal of Endocrinology ENDOCRINOLOGY & METABOLISM-
CiteScore
5.20
自引率
0.00%
发文量
147
审稿时长
1 months
期刊介绍: International Journal of Endocrinology is a peer-reviewed, Open Access journal that provides a forum for scientists and clinicians working in basic and translational research. The journal publishes original research articles, review articles, and clinical studies that provide insights into the endocrine system and its associated diseases at a genomic, molecular, biochemical and cellular level.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信