Indocyanine green guided sentinel lymph node biopsy may have a high sensitivity for early (T1/T2) colon cancer: A prospective study in Indian patients.
Zeeshan Ahmed, Sanjeev M Patil, Anuradha Sekaran, Pradeep Rebala, G V Rao
{"title":"Indocyanine green guided sentinel lymph node biopsy may have a high sensitivity for early (T1/T2) colon cancer: A prospective study in Indian patients.","authors":"Zeeshan Ahmed, Sanjeev M Patil, Anuradha Sekaran, Pradeep Rebala, G V Rao","doi":"10.47717/turkjsurg.2023.6106","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Indocyanine green (ICG) dye guided near infrared fluorescence (NIR) imaging is a promising tool for mapping lymphatics. The aim of this study was to evaluate the role of ICG guided SLN biopsy in Indian colon cancer patients.</p><p><strong>Material and methods: </strong>Forty-eight patients of clinically staged T1-T3 node negative colon cancer underwent laparoscopic/open resection. Patients received colonoscopic peritumoral submucosal ICG injections for laparoscopic (n= 32) and subserosal injections for open resections (n= 16) followed by the detection of SLN using NIR camera. SLNs underwent conventional hematoxylin and eosin (H & E) staging with additional serial sectioning and immunohistochemistry for pancytokeratin antibody (ultra-staging). Detection rate and upstaging rate were the primary end points.</p><p><strong>Results: </strong>Forty-eight patients were recruited. An average of 2.08 ± 1.27 SLNs were identified in 45 patients at a mean time of 8.2 ± 3.68 minutes with a detection rate of 93.75%. Mean age and mean BMI were 59.7 ± 12.54 years and 24.8 ± 4.09 kg/m<sup>2</sup> , respectively. Eighteen patients had node positive disease, and SLN was false negative in four of these patients resulting in a sensitivity of 77.77% with a trend towards higher sensitivity for T1-T2 tumours (90% vs. 62.5%, p= 0.068). Upstaging rate was 10%. Negative predictive value (NPV) and accuracy of the procedure were 87.09% and 91.11%, respectively.</p><p><strong>Conclusion: </strong>ICG guided SLN biopsy can identify metastatic lymph nodes in colon cancer patients that can be missed on H & E staging with relatively higher sensitivity for early (T1/T2) tumours.</p>","PeriodicalId":23374,"journal":{"name":"Turkish Journal of Surgery","volume":"39 3","pages":"190-196"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10696441/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47717/turkjsurg.2023.6106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Indocyanine green (ICG) dye guided near infrared fluorescence (NIR) imaging is a promising tool for mapping lymphatics. The aim of this study was to evaluate the role of ICG guided SLN biopsy in Indian colon cancer patients.
Material and methods: Forty-eight patients of clinically staged T1-T3 node negative colon cancer underwent laparoscopic/open resection. Patients received colonoscopic peritumoral submucosal ICG injections for laparoscopic (n= 32) and subserosal injections for open resections (n= 16) followed by the detection of SLN using NIR camera. SLNs underwent conventional hematoxylin and eosin (H & E) staging with additional serial sectioning and immunohistochemistry for pancytokeratin antibody (ultra-staging). Detection rate and upstaging rate were the primary end points.
Results: Forty-eight patients were recruited. An average of 2.08 ± 1.27 SLNs were identified in 45 patients at a mean time of 8.2 ± 3.68 minutes with a detection rate of 93.75%. Mean age and mean BMI were 59.7 ± 12.54 years and 24.8 ± 4.09 kg/m2 , respectively. Eighteen patients had node positive disease, and SLN was false negative in four of these patients resulting in a sensitivity of 77.77% with a trend towards higher sensitivity for T1-T2 tumours (90% vs. 62.5%, p= 0.068). Upstaging rate was 10%. Negative predictive value (NPV) and accuracy of the procedure were 87.09% and 91.11%, respectively.
Conclusion: ICG guided SLN biopsy can identify metastatic lymph nodes in colon cancer patients that can be missed on H & E staging with relatively higher sensitivity for early (T1/T2) tumours.