Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Alexander Schmidt, Cara Berschin, Bernd Wöstmann, Maximiliane Amelie Schlenz
{"title":"Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study.","authors":"Alexander Schmidt, Cara Berschin, Bernd Wöstmann, Maximiliane Amelie Schlenz","doi":"10.1186/s40729-023-00516-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom implant impressions with polyether. Thus, new approaches using 3-D printed impression trays may increase the transfer accuracy of implant impressions. The ability to adjust parameters such as the thickness of the layers and the influence of the openings in the impression tray could potentially affect accuracy.</p><p><strong>Methods: </strong>Four different types of impression trays (n = 10 for each group) for the conventional impression technique were investigated: conventional custom impression tray, customized foil tray, chairside 3-D printed impression tray with the SHERA system, and the Primeprint system using an implant master model with four implants in the posterior region and a reference cube. After plaster model casting, all models were measured using a coordinate measuring machine, and the deviation from the reference dataset was determined. A statistical ANOVA analysis was performed (p < 0.05).</p><p><strong>Results: </strong>Chairside 3-D printed impression trays showed the best results, followed by conventional custom impression trays. Implant impressions obtained using a customized foil tray exhibited the lowest accuracy. Statistically significant differences were observed between 3-D printed impression trays and conventional custom impression and customized foil trays (p < 0.05). Whereas, the implant position did not have any significant influence on accuracy (p > 0.05).</p><p><strong>Conclusions: </strong>Chairside 3-D printed impression trays significantly increase the transfer accuracy for implant impression taking.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"9 1","pages":"47"},"PeriodicalIF":3.1000,"publicationDate":"2023-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10697909/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-023-00516-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom implant impressions with polyether. Thus, new approaches using 3-D printed impression trays may increase the transfer accuracy of implant impressions. The ability to adjust parameters such as the thickness of the layers and the influence of the openings in the impression tray could potentially affect accuracy.

Methods: Four different types of impression trays (n = 10 for each group) for the conventional impression technique were investigated: conventional custom impression tray, customized foil tray, chairside 3-D printed impression tray with the SHERA system, and the Primeprint system using an implant master model with four implants in the posterior region and a reference cube. After plaster model casting, all models were measured using a coordinate measuring machine, and the deviation from the reference dataset was determined. A statistical ANOVA analysis was performed (p < 0.05).

Results: Chairside 3-D printed impression trays showed the best results, followed by conventional custom impression trays. Implant impressions obtained using a customized foil tray exhibited the lowest accuracy. Statistically significant differences were observed between 3-D printed impression trays and conventional custom impression and customized foil trays (p < 0.05). Whereas, the implant position did not have any significant influence on accuracy (p > 0.05).

Conclusions: Chairside 3-D printed impression trays significantly increase the transfer accuracy for implant impression taking.

椅旁 3-D 打印印模托盘:提高传统种植体印模准确性的新方法?一项体外研究。
目的:在制作种植体支持修复体时,需要将口内种植体的位置高度精确地转移到模型上。然而,口内种植体位置与获得的模型之间仍然存在临床相关性偏差,即使是使用聚醚的基准传统定制种植体印模也是如此。因此,使用 3-D 打印印模托盘的新方法可以提高种植体印模的转移准确性。调整印模托层厚度和开口影响等参数的能力可能会影响印模的准确性:研究了用于传统印模技术的四种不同类型的印模托盘(每组 10 个):传统定制印模托盘、定制铝箔托盘、使用 SHERA 系统的椅旁三维打印印模托盘,以及使用带有后牙区域四个种植体和一个参考立方体的种植体主模型的 Primeprint 系统。石膏模型铸造完成后,使用坐标测量机对所有模型进行测量,并确定与参考数据集的偏差。进行了统计方差分析(P 结果:椅旁三维打印印模托盘的效果最好,其次是传统的定制印模托盘。使用定制铝箔托盘获得的种植体印模准确度最低。3-D 打印印模托盘与传统定制印模托盘和定制箔托盘之间存在明显的统计学差异(P 0.05):结论:椅旁 3-D 打印印模托盘可显著提高种植体印模的转移准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信