Caloric function as a predictor of cochlear implant performance.

IF 1.4 Q2 OTORHINOLARYNGOLOGY
COCHLEAR IMPLANTS INTERNATIONAL Pub Date : 2024-01-01 Epub Date: 2023-11-30 DOI:10.1080/14670100.2023.2286165
Alexandra E Quimby, Christopher Z Wen, Michael J Ruckenstein, Jason A Brant, Douglas C Bigelow
{"title":"Caloric function as a predictor of cochlear implant performance.","authors":"Alexandra E Quimby, Christopher Z Wen, Michael J Ruckenstein, Jason A Brant, Douglas C Bigelow","doi":"10.1080/14670100.2023.2286165","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Changes in vestibular function have been demonstrated following cochlear implantation (CI). The functional impact of these changes on CI performance has not been well-studied. We sought to assess whether caloric changes postimplantation could predict CI performance.</p><p><strong>Methods: </strong>Retrospective review of a prospectively collected database at a tertiary care hospital. Patients who underwent CI over a 22-year period (1999-2021) and had videonystagmography (VNG) testing pre- and postimplantation were included. Caloric responses were compared pre- versus post-implantation, and assessed for their ability to predict CI performance as evaluated using AzBio +10 decibels signal-to-noise ratio (dB S/N) scores.</p><p><strong>Results: </strong>43 CI recipients were included. There was a significant difference in the average maximal slow-phase velocity in response to caloric irrigation in the implanted ear pre- versus post-operatively (21.2 vs. 18.5 deg/s; <i>p</i> = 0.02). Controlling for age and pre-implantation speech recognition performance, pre- and post-implantation caloric responses in the implanted ear significantly predicted CI performance at 0-6 months and >6 months post-implantation. Caloric changes following implantation were not significantly correlated with CI performance.</p><p><strong>Conclusion: </strong>CI impacts vestibular function as evidenced by changes in caloric responses. Vestibular function pre- and possibly post-CI may be clinically useful metrics for predicting some proportion of CI performance variability.</p>","PeriodicalId":53553,"journal":{"name":"COCHLEAR IMPLANTS INTERNATIONAL","volume":" ","pages":"28-35"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"COCHLEAR IMPLANTS INTERNATIONAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14670100.2023.2286165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Changes in vestibular function have been demonstrated following cochlear implantation (CI). The functional impact of these changes on CI performance has not been well-studied. We sought to assess whether caloric changes postimplantation could predict CI performance.

Methods: Retrospective review of a prospectively collected database at a tertiary care hospital. Patients who underwent CI over a 22-year period (1999-2021) and had videonystagmography (VNG) testing pre- and postimplantation were included. Caloric responses were compared pre- versus post-implantation, and assessed for their ability to predict CI performance as evaluated using AzBio +10 decibels signal-to-noise ratio (dB S/N) scores.

Results: 43 CI recipients were included. There was a significant difference in the average maximal slow-phase velocity in response to caloric irrigation in the implanted ear pre- versus post-operatively (21.2 vs. 18.5 deg/s; p = 0.02). Controlling for age and pre-implantation speech recognition performance, pre- and post-implantation caloric responses in the implanted ear significantly predicted CI performance at 0-6 months and >6 months post-implantation. Caloric changes following implantation were not significantly correlated with CI performance.

Conclusion: CI impacts vestibular function as evidenced by changes in caloric responses. Vestibular function pre- and possibly post-CI may be clinically useful metrics for predicting some proportion of CI performance variability.

热功能作为人工耳蜗植入性能的预测指标。
目的:耳蜗植入(CI)后前庭功能的改变已被证实。这些变化对CI性能的功能影响尚未得到充分研究。我们试图评估植入术后的热量变化是否可以预测CI的表现。方法:对一家三级医院前瞻性收集的数据库进行回顾性分析。在22年期间(1999-2021年)接受CI治疗并在植入前后进行了视频颤振仪(VNG)检测的患者被纳入研究。通过AzBio +10分贝信噪比(dB S/N)评分,比较了植入前和植入后的热反应,并评估了其预测CI性能的能力。结果:纳入43例CI患者。术前与术后植入耳内热灌的平均最大慢相速度有显著差异(21.2对18.5度/秒;p = 0.02)。控制年龄和植入前语音识别性能,植入前和植入后耳部的热量反应显著预测植入后0-6个月和>6个月的CI表现。植入后的热量变化与CI性能无显著相关。结论:CI影响前庭功能,其证据是热量反应的改变。前庭功能在CI前和可能的CI后可能是临床有用的指标,用于预测CI表现变异性的一定比例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
COCHLEAR IMPLANTS INTERNATIONAL
COCHLEAR IMPLANTS INTERNATIONAL Medicine-Otorhinolaryngology
CiteScore
3.10
自引率
0.00%
发文量
29
期刊介绍: Cochlear Implants International was founded as an interdisciplinary, peer-reviewed journal in response to the growing number of publications in the field of cochlear implants. It was designed to meet a need to include scientific contributions from all the disciplines that are represented in cochlear implant teams: audiology, medicine and surgery, speech therapy and speech pathology, psychology, hearing therapy, radiology, pathology, engineering and acoustics, teaching, and communication. The aim was to found a truly interdisciplinary journal, representing the full breadth of the field of cochlear implantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信