Daniel A Tonetti, Manisha Koneru, Meghna Bhattacharyya, Joey D English, Fabio Settecase, Warren T Kim, Jane Khalife, Pratit Patel, Ajith Thomas, Tudor Jovin, Ricardo Hanel, Victor H C Benalia, Gustavo M Cortez, Amin Aghaebrahim, Eric Sauvageau, Mohamad Abdalkader, Thanh N Nguyen, Piers Klein, Adam A Dmytriw, Hamza Shaikh
{"title":"Tenzing 7 delivery catheter with or without a leading microwire for single pass aspiration thrombectomy: A multicenter experience.","authors":"Daniel A Tonetti, Manisha Koneru, Meghna Bhattacharyya, Joey D English, Fabio Settecase, Warren T Kim, Jane Khalife, Pratit Patel, Ajith Thomas, Tudor Jovin, Ricardo Hanel, Victor H C Benalia, Gustavo M Cortez, Amin Aghaebrahim, Eric Sauvageau, Mohamad Abdalkader, Thanh N Nguyen, Piers Klein, Adam A Dmytriw, Hamza Shaikh","doi":"10.1177/15910199231216765","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Aspiration mechanical thrombectomy traditionally includes use of an inner microcatheter and leading microwire to navigate an aspiration catheter (AC) to the site of occlusion. Early clinical experience suggests that a leading microwire is often not needed with the Tenzing 7 (T7, Route 92 Medical, San Mateo, CA), a soft tapered tip ledge-reducing delivery catheter. This multicenter experience aims to describe AC delivery success in single-pass thrombectomy using T7 with and without a leading microwire.</p><p><strong>Methods: </strong>A retrospective review was conducted of consecutive patients who underwent single-pass thrombectomy with T7 at six institutions between 2020 and 2022. We examined the percentage of successful AC delivery, puncture-to-revascularization time, and procedural complication rate.</p><p><strong>Results: </strong>A leading microwire with T7 was used in 19/89 (21%) of patients, and it was not used with T7 in 70/89 (79%) of patients. Successful AC delivery was similar with and without microwires (97% vs. 90%, p = 0.15). Median puncture-to-revascularization times were similar (17 min microwire vs. 16 min no-microwire, p = 0.12). No complications were associated with microwire use; one (1.4%) patient had a T7-related vasospasm resolved with verapamil during thrombectomy without a leading microwire. Differences in complication rates were not statistically significant (p = 0.46).</p><p><strong>Conclusion: </strong>In our real-world clinical experience, leading microwire use was infrequently necessary with the T7 delivery catheter. Successful AC delivery and complication rates were similar with and without microwire use in single-pass T7 thrombectomies. Initial pass with T7 may be performed without use of leading microwire, reserving microwire use for refractory cases or known difficult-to-navigate vasculature.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199231216765","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Aspiration mechanical thrombectomy traditionally includes use of an inner microcatheter and leading microwire to navigate an aspiration catheter (AC) to the site of occlusion. Early clinical experience suggests that a leading microwire is often not needed with the Tenzing 7 (T7, Route 92 Medical, San Mateo, CA), a soft tapered tip ledge-reducing delivery catheter. This multicenter experience aims to describe AC delivery success in single-pass thrombectomy using T7 with and without a leading microwire.
Methods: A retrospective review was conducted of consecutive patients who underwent single-pass thrombectomy with T7 at six institutions between 2020 and 2022. We examined the percentage of successful AC delivery, puncture-to-revascularization time, and procedural complication rate.
Results: A leading microwire with T7 was used in 19/89 (21%) of patients, and it was not used with T7 in 70/89 (79%) of patients. Successful AC delivery was similar with and without microwires (97% vs. 90%, p = 0.15). Median puncture-to-revascularization times were similar (17 min microwire vs. 16 min no-microwire, p = 0.12). No complications were associated with microwire use; one (1.4%) patient had a T7-related vasospasm resolved with verapamil during thrombectomy without a leading microwire. Differences in complication rates were not statistically significant (p = 0.46).
Conclusion: In our real-world clinical experience, leading microwire use was infrequently necessary with the T7 delivery catheter. Successful AC delivery and complication rates were similar with and without microwire use in single-pass T7 thrombectomies. Initial pass with T7 may be performed without use of leading microwire, reserving microwire use for refractory cases or known difficult-to-navigate vasculature.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...