Post-cure Heat Treatments Influence the Mechanical and Optical Properties of Acrylic and Bis-acryl Composite Resins.

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
L B Morgado, M S Pedrosa, I S Medeiros
{"title":"Post-cure Heat Treatments Influence the Mechanical and Optical Properties of Acrylic and Bis-acryl Composite Resins.","authors":"L B Morgado, M S Pedrosa, I S Medeiros","doi":"10.2341/23-011-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the influence of post-cure heat treatments (PCHT) on Knoop microhardness (KHN) and color change of bis-acryl composite resin (Protemp 4 - 3M ESPE, USA and PrimmaArt - FGM, Brazil) and chemically activated acrylic resins (Dencôr - Clássico, Brazil, and Duralay - Cotia, Brazil).</p><p><strong>Methods and materials: </strong>Specimens (12×1 mm) were prepared for each material (n=10/group). Thirty minutes after curing, the specimens were subjected to PCHT for 10 minutes at 70°, 100°, or 130°C. The control group was kept at room temperature (24°C) for the same amount of time. KHN was analyzed 24 hours after PCHT (n=10). Following Commission Internationale de l'Éclairage (CIE) Delta E 2000 (CIEDE2000 [ΔE00]), color measurements were obtained at three time points: 1. after polymerization; 2. after PCHT; and 3. after 30 days of storage in water, coffee, or red wine. Data for each material were analyzed by one-way analysis of variance (ANOVA) (p<0.05).</p><p><strong>Results: </strong>The PCHT at 130°C produced the highest KHN values. Except for the 70°C groups from Dencôr and Protemp, all PCHTs increased the initial color values (p>0.05). In general, chemically activated acrylic resins showed an increase in color stability when subjected to PCHT (p>0.05). For bis-acryl composite resin, PCHT did not influence color stability (p<0.05).</p><p><strong>Conclusion: </strong>Overall, the results showed that PCHT increased the tested materials' color changes and Knoop microhardness. However, except for PCHT at 130°C in Duralay, the color changes remained within acceptable values. The PCHT treatment resulted in better color stability for most of the composite resins studied.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"76-83"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-011-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the influence of post-cure heat treatments (PCHT) on Knoop microhardness (KHN) and color change of bis-acryl composite resin (Protemp 4 - 3M ESPE, USA and PrimmaArt - FGM, Brazil) and chemically activated acrylic resins (Dencôr - Clássico, Brazil, and Duralay - Cotia, Brazil).

Methods and materials: Specimens (12×1 mm) were prepared for each material (n=10/group). Thirty minutes after curing, the specimens were subjected to PCHT for 10 minutes at 70°, 100°, or 130°C. The control group was kept at room temperature (24°C) for the same amount of time. KHN was analyzed 24 hours after PCHT (n=10). Following Commission Internationale de l'Éclairage (CIE) Delta E 2000 (CIEDE2000 [ΔE00]), color measurements were obtained at three time points: 1. after polymerization; 2. after PCHT; and 3. after 30 days of storage in water, coffee, or red wine. Data for each material were analyzed by one-way analysis of variance (ANOVA) (p<0.05).

Results: The PCHT at 130°C produced the highest KHN values. Except for the 70°C groups from Dencôr and Protemp, all PCHTs increased the initial color values (p>0.05). In general, chemically activated acrylic resins showed an increase in color stability when subjected to PCHT (p>0.05). For bis-acryl composite resin, PCHT did not influence color stability (p<0.05).

Conclusion: Overall, the results showed that PCHT increased the tested materials' color changes and Knoop microhardness. However, except for PCHT at 130°C in Duralay, the color changes remained within acceptable values. The PCHT treatment resulted in better color stability for most of the composite resins studied.

固化后热处理对丙烯酸和双丙烯酸复合树脂机械和光学性能的影响。
目的:评价固化后热处理(PCHT)对双丙烯酸基复合树脂(Protemp 4 - 3M ESPE,美国,PrimmaArt - FGM,巴西)和化学活化丙烯酸树脂(Dencôr - Clássico,巴西,Duralay - Cotia)的Knoop显微硬度(KHN)和颜色变化的影响。方法和材料:每种材料制备标本(12×1 mm) (n=10/组)。固化30分钟后,标本在70°、100°或130°C下进行PCHT 10分钟。对照组在室温(24°C)下保存相同时间。PCHT术后24小时分析KHN (n=10)。根据国际委员会Éclairage (CIE) Delta E2000 (CIEDE2000 [ΔE00]),在三个时间点获得了颜色测量值:后聚合;2. PCHT后;和3。在水、咖啡或红酒中存放30天后。每种材料的数据通过单因素方差分析(ANOVA)进行分析(结果:130°C时的PCHT产生最高的KHN值。除了Dencôr和Protemp的70°C组外,所有PCHTs均使初始颜色值升高(p>0.05)。总的来说,化学活化的丙烯酸树脂在PCHT作用下的颜色稳定性有所提高(p>0.05)。对于双丙烯酸酯复合树脂,PCHT对颜色稳定性没有影响(p结论:总体而言,PCHT增加了被测材料的颜色变化和努氏显微硬度。然而,除了Duralay在130°C时的PCHT外,颜色变化仍在可接受的范围内。经PCHT处理后,所研究的大多数复合树脂具有较好的颜色稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信