Ecofriendly HPLC Method for Simultaneous Determination of the Co-Prescribed Drugs in Chemotherapy Omeprazole, Ondansetron and Deflazacort in Spiked Human Plasma.
Fatma F Abdallah, M Fatma, Ahmed M Gouda, Eglal A Abdelaleem, Aml A Emam
{"title":"Ecofriendly HPLC Method for Simultaneous Determination of the Co-Prescribed Drugs in Chemotherapy Omeprazole, Ondansetron and Deflazacort in Spiked Human Plasma.","authors":"Fatma F Abdallah, M Fatma, Ahmed M Gouda, Eglal A Abdelaleem, Aml A Emam","doi":"10.1093/chromsci/bmad088","DOIUrl":null,"url":null,"abstract":"<p><p>Green, selective and accurate high-performance liquid chromatography (HPLC) chromatographic method is presented for simultaneous separation and quantitation of the co-prescribed drugs in chemotherapy omeprazole, ondansetron and deflazacort in spiked human plasma. An isocratic HPLC separation was performed on X Bridge C18 (4.6 × 250 mm) column with 5 μm particle size using mobile phase consisting of methanol: ammonium acetate buffer pH 4 adjusted by acetic acid (60: 40, v/v). The injection volume was 20μL with UV detection wavelength at 237 nm at room temperature. Flow rate of the mobile phase was adjusted to be 2.0 ml/min. Dexamethasone was used as internal standard to correct the variation during sample pretreatment. FDA guidelines were followed to validate the developed method. Successful application of the developed method was revealed by simultaneous determination of omeprazole, ondansetron and deflazacort in spiked human plasma in ranges of 1-20, 0.1-8 and 0.2-8 μg mL-1 for omeprazole, ondansetron and deflazacort, respectively. Four greenness assessment tools were used to evaluate the greenness of the developed method and the results were accepted. This method permitted the accurate simultaneous determination of the studied drugs, thus it can be used during therapeutic drug monitoring in daily clinical practice.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"845-853"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmad088","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Green, selective and accurate high-performance liquid chromatography (HPLC) chromatographic method is presented for simultaneous separation and quantitation of the co-prescribed drugs in chemotherapy omeprazole, ondansetron and deflazacort in spiked human plasma. An isocratic HPLC separation was performed on X Bridge C18 (4.6 × 250 mm) column with 5 μm particle size using mobile phase consisting of methanol: ammonium acetate buffer pH 4 adjusted by acetic acid (60: 40, v/v). The injection volume was 20μL with UV detection wavelength at 237 nm at room temperature. Flow rate of the mobile phase was adjusted to be 2.0 ml/min. Dexamethasone was used as internal standard to correct the variation during sample pretreatment. FDA guidelines were followed to validate the developed method. Successful application of the developed method was revealed by simultaneous determination of omeprazole, ondansetron and deflazacort in spiked human plasma in ranges of 1-20, 0.1-8 and 0.2-8 μg mL-1 for omeprazole, ondansetron and deflazacort, respectively. Four greenness assessment tools were used to evaluate the greenness of the developed method and the results were accepted. This method permitted the accurate simultaneous determination of the studied drugs, thus it can be used during therapeutic drug monitoring in daily clinical practice.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.