{"title":"Energy, Exergy, and Environment Performance Evaluation of Cascade Refrigeration System with Natural Refrigerants","authors":"Meltem KOŞAN","doi":"10.17350/hjse19030000313","DOIUrl":null,"url":null,"abstract":"Cascade refrigeration systems are preferred in applications where low temperature cooling is required, such as in some special industrial and laboratory applications. Since, in these systems, the energy consumed by the compressors is less and the compressor outlet temperature is lower. Due to environmental problems, the use of natural refrigerants in cascade refrigeration systems has become to be of great importance. In this study, two cascade systems consisting of R744/R290 (System 1) and R1270/R290 (System 2) natural refrigerant pairs were designed and thermodynamically examined. In the analyzes performed according to different evaporator temperatures, the highest COP value was 3.66 at -20℃ evaporating temperature was obtained in the cascade system consisting of the R1270/R290 refrigerant pair. Moreover, it was considered that there was a 17.95% enhancement in exergy efficiency with the use of R1270 refrigerant in the low temperature cycle. By the rise in the evaporator temperature, energy consumption decreases and as a result, the amount of carbon dioxide emissions reduced was attained.","PeriodicalId":500702,"journal":{"name":"Hitite journal of science and engineering","volume":"1129 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hitite journal of science and engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17350/hjse19030000313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Cascade refrigeration systems are preferred in applications where low temperature cooling is required, such as in some special industrial and laboratory applications. Since, in these systems, the energy consumed by the compressors is less and the compressor outlet temperature is lower. Due to environmental problems, the use of natural refrigerants in cascade refrigeration systems has become to be of great importance. In this study, two cascade systems consisting of R744/R290 (System 1) and R1270/R290 (System 2) natural refrigerant pairs were designed and thermodynamically examined. In the analyzes performed according to different evaporator temperatures, the highest COP value was 3.66 at -20℃ evaporating temperature was obtained in the cascade system consisting of the R1270/R290 refrigerant pair. Moreover, it was considered that there was a 17.95% enhancement in exergy efficiency with the use of R1270 refrigerant in the low temperature cycle. By the rise in the evaporator temperature, energy consumption decreases and as a result, the amount of carbon dioxide emissions reduced was attained.
天然制冷剂梯级制冷系统的能源、能源和环境性能评价
在需要低温冷却的应用中,例如在一些特殊的工业和实验室应用中,梯级制冷系统是首选。因为,在这些系统中,压缩机消耗的能量更少,压缩机出口温度更低。由于环境问题,在复叠式制冷系统中使用天然制冷剂已变得非常重要。本研究设计了由R744/R290(系统1)和R1270/R290(系统2)天然制冷剂对组成的两个叶栅系统,并对其进行了热力学测试。根据不同的蒸发器温度进行分析,在由R1270/R290制冷剂对组成的叶栅系统中,在蒸发温度为-20℃时COP值最高,为3.66。此外,在低温循环中使用R1270制冷剂可以提高17.95%的火用效率。由于蒸发器温度的升高,能耗降低,从而达到减少二氧化碳排放量的目的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信