{"title":"RANCANG BANGUN ALAT PENDETEKSI GOLONGAN DARAH DAN SATURASI OKSIGEN BERBASIS ARDUINO UNO","authors":"Ahmad Halim, Ganis Sanhaji, Yudha Aria Praja","doi":"10.47668/edusaintek.v11i1.962","DOIUrl":null,"url":null,"abstract":"In this study a device was designed to detect human blood group using the ABO method which is integrated with a blood oxygen saturation meter. This tool can detect agglutination or non-agglutination reactions in blood samples that have been treated with antisera and will then be read by three TCRT5000 sensors which are reflective sensors used as detectors of A, B and Rhesus antigens when agglutination and non-agglutination reactions occur on paper. blood sample test. In addition, the MAX30100 sensor is also used to measure blood oxygen saturation in the human body. Data that has been read by the sensor will be directly processed by Arduino Uno and the results from reading by the sensor will be displayed on the 16x2 LCD. In testing the human blood group detector designed where the results of all tests on the respondent's blood samples totaling 8 blood samples obtained a success value of 100%. In addition, the results of testing the Oxygen Saturation Measuring Instrument using the MAX30100 sensor obtained an accuracy value of 99.53%.","PeriodicalId":500517,"journal":{"name":"Edusaintek","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Edusaintek","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47668/edusaintek.v11i1.962","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study a device was designed to detect human blood group using the ABO method which is integrated with a blood oxygen saturation meter. This tool can detect agglutination or non-agglutination reactions in blood samples that have been treated with antisera and will then be read by three TCRT5000 sensors which are reflective sensors used as detectors of A, B and Rhesus antigens when agglutination and non-agglutination reactions occur on paper. blood sample test. In addition, the MAX30100 sensor is also used to measure blood oxygen saturation in the human body. Data that has been read by the sensor will be directly processed by Arduino Uno and the results from reading by the sensor will be displayed on the 16x2 LCD. In testing the human blood group detector designed where the results of all tests on the respondent's blood samples totaling 8 blood samples obtained a success value of 100%. In addition, the results of testing the Oxygen Saturation Measuring Instrument using the MAX30100 sensor obtained an accuracy value of 99.53%.
设计一个血型检测设备和基于ARDUINO UNO的氧饱和度
本研究设计了一种结合血氧饱和度仪的ABO法检测人体血型的装置。该工具可以检测用抗血清处理过的血液样本中的凝集或非凝集反应,然后由三个TCRT5000传感器读取,TCRT5000传感器是在纸上发生凝集和非凝集反应时用作A, B和恒河抗原检测器的反射传感器。血液样本测试。此外,MAX30100传感器还用于测量人体的血氧饱和度。传感器读取到的数据将由Arduino Uno直接处理,传感器读取的结果将显示在16x2的LCD上。在测试设计的人类血型检测器中,对被调查者的血样(总共8个血样)的所有测试结果获得了100%的成功值。此外,利用MAX30100传感器对氧饱和度测试仪进行测试,获得了99.53%的精度值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信