“Air and Visco” Technique: A Promising Innovation in the Surgical Implantation of the Xen Gel Stent Device

Vision Pub Date : 2023-11-02 DOI:10.3390/vision7040071
Fabrizio Franco, Federica Serino, Fabrizio Giansanti
{"title":"“Air and Visco” Technique: A Promising Innovation in the Surgical Implantation of the Xen Gel Stent Device","authors":"Fabrizio Franco, Federica Serino, Fabrizio Giansanti","doi":"10.3390/vision7040071","DOIUrl":null,"url":null,"abstract":"We aimed to describe a variation of the surgical technique for the ab interno implantation of the XEN Gel Stent, which, in our experience, is yielding very successful results. The injection of 0.1 mL of air and then of 0.1 mL of a dispersive viscoelastic into the subconjunctival space at the beginning of the surgery allows one to perform a mechanical dissection between the conjunctiva and the Tenon’s capsule, creating a real space. In total, 20 eyes of 16 patients underwent the implantation of a stent gel through the “Air and Visco” technique. We retrospectively analyzed the results. We obtained a reduction in the IOP from an average of 18.3 ± 2.2 mmHg preoperatively to at 13.5 ± 3.5 mmHg at month 12. The needling rate was 20%. We did not register any cases of hypotony (IOP < 6 mmHg), hypotony maculopathy or choroidal detachment. The “Air and Visco” technique allows one to correctly place the device in the subconjunctival space, which the pneumo- and visco-dissection transforms into a real space. This enables an easier surgical performance and more predictable postoperative results, with a low needling rate and reintervention in the follow-up period. It also ensures a greater safety profile because the presence of the OVD on the bleb prevents a sudden lowering of the IOP, eliminating complications such as hypotony, hypotony maculopathy and choroidal detachment in our cohort.","PeriodicalId":23649,"journal":{"name":"Vision","volume":"1 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision7040071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We aimed to describe a variation of the surgical technique for the ab interno implantation of the XEN Gel Stent, which, in our experience, is yielding very successful results. The injection of 0.1 mL of air and then of 0.1 mL of a dispersive viscoelastic into the subconjunctival space at the beginning of the surgery allows one to perform a mechanical dissection between the conjunctiva and the Tenon’s capsule, creating a real space. In total, 20 eyes of 16 patients underwent the implantation of a stent gel through the “Air and Visco” technique. We retrospectively analyzed the results. We obtained a reduction in the IOP from an average of 18.3 ± 2.2 mmHg preoperatively to at 13.5 ± 3.5 mmHg at month 12. The needling rate was 20%. We did not register any cases of hypotony (IOP < 6 mmHg), hypotony maculopathy or choroidal detachment. The “Air and Visco” technique allows one to correctly place the device in the subconjunctival space, which the pneumo- and visco-dissection transforms into a real space. This enables an easier surgical performance and more predictable postoperative results, with a low needling rate and reintervention in the follow-up period. It also ensures a greater safety profile because the presence of the OVD on the bleb prevents a sudden lowering of the IOP, eliminating complications such as hypotony, hypotony maculopathy and choroidal detachment in our cohort.
“空气与黏液”技术:Xen凝胶支架植入手术中的一项有前途的创新
我们的目的是描述一种手术技术的变化,用于腹腔植入XEN凝胶支架,根据我们的经验,它产生了非常成功的结果。在手术开始时,向结膜下空间注射0.1 mL空气和0.1 mL弥散性粘弹性物质,这样就可以在结膜和Tenon 's capsule之间进行机械解剖,创造一个真正的空间。16例患者共20只眼通过“Air and Visco”技术植入支架凝胶。我们对结果进行回顾性分析。我们发现IOP从术前平均18.3±2.2 mmHg下降到12个月时的13.5±3.5 mmHg。针刺率为20%。我们没有记录到任何低眼压(IOP <6 mmHg),黄斑低压性病变或脉络膜脱离。“空气和黏液”技术允许人们将设备正确地放置在结膜下空间,空气和黏液分离将其转化为真实空间。这使得手术操作更容易,术后结果更可预测,针刺率低,随访期间再次干预。它还确保了更大的安全性,因为泡上的OVD的存在可以防止IOP突然降低,消除了我们队列中的低眼压、低眼压黄斑病变和脉络膜脱离等并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信