The value of early diagnosis of acute myocardial infarction of the high-sensitivity Troponin I assay on the Atellica analyzer

Thi Ngoc Lan Nguyen, Thi Thu Huong Phan
{"title":"The value of early diagnosis of acute myocardial infarction of the high-sensitivity Troponin I assay on the Atellica analyzer","authors":"Thi Ngoc Lan Nguyen, Thi Thu Huong Phan","doi":"10.31276/vjst.65(9).34-38","DOIUrl":null,"url":null,"abstract":"Laboratory tests play an extremely important role in the diagnosis of acute myocardial infarction (MI), helping clinicians to make early decisions on patients with suspected MI. Thereby helping to increase the effectiveness of treatment, reduce the rate of complications after MI, and increase the survival rate of MI patients. Troponin is a component of the muscle contraction complex, which has been used as a diagnostic marker of MI in clinical practice with the high-sensitivity Troponin T and Troponin I types. At Hanoi Medical University Hospital, before deploying the high-sensitivity Troponin I assay, validation was conducted to compare the performance of the method surveyed by the laboratory with the manufacturer’s announcements. And especially investigating the diagnostic value of acute coronary syndromes of the high-sensitivity Troponin I assay. Validation results of the high-sensitivity troponin I test method all meet the standards of the Clinical and Laboratory Standards Institute (CLSI) and the manufacturer’s announcement. The sensitivity, specificity and area under the curve (AUC) of the high-sensitivity Troponin I assay on the Atellica analyzer were 90.2, 78.7, and 0.881%, respectively. Thus, the technical characteristics of the high-sensitivity Troponin I assay with precision, accuracy, linear range, LoD, and LoQ meet the standards of CLSI and the manufacturer. The study has demonstrated the effectiveness of the high-sensitivity Troponin I assay in the diagnosis and prognosis of acute MI.","PeriodicalId":494861,"journal":{"name":"Tạp chí Khoa học và Công nghệ Việt Nam","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tạp chí Khoa học và Công nghệ Việt Nam","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31276/vjst.65(9).34-38","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Laboratory tests play an extremely important role in the diagnosis of acute myocardial infarction (MI), helping clinicians to make early decisions on patients with suspected MI. Thereby helping to increase the effectiveness of treatment, reduce the rate of complications after MI, and increase the survival rate of MI patients. Troponin is a component of the muscle contraction complex, which has been used as a diagnostic marker of MI in clinical practice with the high-sensitivity Troponin T and Troponin I types. At Hanoi Medical University Hospital, before deploying the high-sensitivity Troponin I assay, validation was conducted to compare the performance of the method surveyed by the laboratory with the manufacturer’s announcements. And especially investigating the diagnostic value of acute coronary syndromes of the high-sensitivity Troponin I assay. Validation results of the high-sensitivity troponin I test method all meet the standards of the Clinical and Laboratory Standards Institute (CLSI) and the manufacturer’s announcement. The sensitivity, specificity and area under the curve (AUC) of the high-sensitivity Troponin I assay on the Atellica analyzer were 90.2, 78.7, and 0.881%, respectively. Thus, the technical characteristics of the high-sensitivity Troponin I assay with precision, accuracy, linear range, LoD, and LoQ meet the standards of CLSI and the manufacturer. The study has demonstrated the effectiveness of the high-sensitivity Troponin I assay in the diagnosis and prognosis of acute MI.
Atellica分析仪高灵敏度肌钙蛋白I检测对急性心肌梗死的早期诊断价值
实验室检查在急性心肌梗死(acute myocardial infarction, MI)的诊断中具有极其重要的作用,可以帮助临床医生对疑似MI患者进行早期决策,从而有助于提高治疗的有效性,降低MI后并发症的发生率,提高MI患者的生存率。肌钙蛋白是肌肉收缩复合体的一种成分,在临床实践中与高灵敏度的肌钙蛋白T和肌钙蛋白I型一起被用作心肌梗死的诊断标志物。在河内医科大学医院,在部署高灵敏度肌钙蛋白1测定法之前,进行了验证,以比较实验室调查的方法与制造商公告的性能。特别探讨高灵敏度肌钙蛋白I测定对急性冠脉综合征的诊断价值。高灵敏度肌钙蛋白I检测方法的验证结果均符合临床与实验室标准协会(CLSI)的标准和制造商公告的标准。高灵敏度肌钙蛋白I在Atellica分析仪上的灵敏度、特异度和曲线下面积(AUC)分别为90.2、78.7和0.881%。因此,高灵敏度肌钙蛋白1测定的精密度、准确度、线性范围、LoD和LoQ符合CLSI和制造商的标准。该研究证明了高灵敏度肌钙蛋白I检测在急性心肌梗死诊断和预后中的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信