{"title":"Method Validation and Monitoring of N-nitrosodimethylamine in Metformin Hydrochloride Products in China by GC-MS/MS","authors":"Jiajia Zou, Lin Yang, Xiaoli Xu, Yan Li, Dan He","doi":"10.2174/0115734129250659230929105800","DOIUrl":null,"url":null,"abstract":"Background:: N-nitrosodimethylamine (NDMA) are a sort of genotoxic impurities (GTIs) having strong carcinogenic effects and obvious hepatotoxicity. To monitor the NDMA content of metformin hydrochloride sustained-release tablets and enteric capsules in China from 2018 to 2022, a GC-MS/MS method was established and validated. background: N-nitrosodimethylamine (NDMA) is a sort of genotoxic impurities (GTIs) which has strong carcinogenic effect and obvious hepatotoxicity. To monitor NDMA content of in Metformin Hydrochloride Sustained-release Tablets and Enteric Capsules in China from 2018 to 2022, a GC-MS/MS method was established and verified. Methods:: The chromatographic column was Agilent VF-WAXms capillary column (30 m×0.25 mm, 0.25 μm). The GC-MS/MS method was equipped with multiple reaction monitoring (MRM) modes. To assess the quantity of NDMA, the molecular ion at mass-to-charge (m/z) of 74-44 was monitored under the 6 V collision energy, and to assess the quality of NDMA monitoring, the molecular ions at m/z 74-42 were determined. A total of 143 batches of metformin hydrochloride-finished products from 35 enterprises were determined by this method. Results:: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection and quantitation were 0.06 ng/mL and 0.21 ng/mL, respectively. The average recovery was 98.62%, and the RSD was 4.31%. All batches of enteric capsules met the requirements; 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. Conclusion:: The presented method is sensitive, accurate, precise, and available for both enteric capsules and sustained-release tablets of metformin hydrochloride, which can provide a reference for their quality control. The over-limit phenomenon of NDMA in metformin hydrochloride products poses new challenges and requirements for both the State Drug Administration and enterprises. result: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection was 0.21 ng/mL. The average recovery was 98.62 %, and the RSD was 4.31%. All batches of enteric capsules met the requirements, 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. other: nothing","PeriodicalId":10889,"journal":{"name":"Current Pharmaceutical Analysis","volume":"16 1","pages":"0"},"PeriodicalIF":0.7000,"publicationDate":"2023-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/0115734129250659230929105800","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
Background:: N-nitrosodimethylamine (NDMA) are a sort of genotoxic impurities (GTIs) having strong carcinogenic effects and obvious hepatotoxicity. To monitor the NDMA content of metformin hydrochloride sustained-release tablets and enteric capsules in China from 2018 to 2022, a GC-MS/MS method was established and validated. background: N-nitrosodimethylamine (NDMA) is a sort of genotoxic impurities (GTIs) which has strong carcinogenic effect and obvious hepatotoxicity. To monitor NDMA content of in Metformin Hydrochloride Sustained-release Tablets and Enteric Capsules in China from 2018 to 2022, a GC-MS/MS method was established and verified. Methods:: The chromatographic column was Agilent VF-WAXms capillary column (30 m×0.25 mm, 0.25 μm). The GC-MS/MS method was equipped with multiple reaction monitoring (MRM) modes. To assess the quantity of NDMA, the molecular ion at mass-to-charge (m/z) of 74-44 was monitored under the 6 V collision energy, and to assess the quality of NDMA monitoring, the molecular ions at m/z 74-42 were determined. A total of 143 batches of metformin hydrochloride-finished products from 35 enterprises were determined by this method. Results:: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection and quantitation were 0.06 ng/mL and 0.21 ng/mL, respectively. The average recovery was 98.62%, and the RSD was 4.31%. All batches of enteric capsules met the requirements; 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. Conclusion:: The presented method is sensitive, accurate, precise, and available for both enteric capsules and sustained-release tablets of metformin hydrochloride, which can provide a reference for their quality control. The over-limit phenomenon of NDMA in metformin hydrochloride products poses new challenges and requirements for both the State Drug Administration and enterprises. result: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection was 0.21 ng/mL. The average recovery was 98.62 %, and the RSD was 4.31%. All batches of enteric capsules met the requirements, 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. other: nothing
期刊介绍:
Aims & Scope
Current Pharmaceutical Analysis publishes expert reviews and original research articles on all the most recent advances in pharmaceutical and biomedical analysis. All aspects of the field are represented including drug analysis, analytical methodology and instrumentation. The journal is essential to all involved in pharmaceutical, biochemical and clinical analysis.