Method Validation and Monitoring of N-nitrosodimethylamine in Metformin Hydrochloride Products in China by GC-MS/MS

IF 0.7 4区 医学 Q4 PHARMACOLOGY & PHARMACY
Jiajia Zou, Lin Yang, Xiaoli Xu, Yan Li, Dan He
{"title":"Method Validation and Monitoring of N-nitrosodimethylamine in Metformin Hydrochloride Products in China by GC-MS/MS","authors":"Jiajia Zou, Lin Yang, Xiaoli Xu, Yan Li, Dan He","doi":"10.2174/0115734129250659230929105800","DOIUrl":null,"url":null,"abstract":"Background:: N-nitrosodimethylamine (NDMA) are a sort of genotoxic impurities (GTIs) having strong carcinogenic effects and obvious hepatotoxicity. To monitor the NDMA content of metformin hydrochloride sustained-release tablets and enteric capsules in China from 2018 to 2022, a GC-MS/MS method was established and validated. background: N-nitrosodimethylamine (NDMA) is a sort of genotoxic impurities (GTIs) which has strong carcinogenic effect and obvious hepatotoxicity. To monitor NDMA content of in Metformin Hydrochloride Sustained-release Tablets and Enteric Capsules in China from 2018 to 2022, a GC-MS/MS method was established and verified. Methods:: The chromatographic column was Agilent VF-WAXms capillary column (30 m×0.25 mm, 0.25 μm). The GC-MS/MS method was equipped with multiple reaction monitoring (MRM) modes. To assess the quantity of NDMA, the molecular ion at mass-to-charge (m/z) of 74-44 was monitored under the 6 V collision energy, and to assess the quality of NDMA monitoring, the molecular ions at m/z 74-42 were determined. A total of 143 batches of metformin hydrochloride-finished products from 35 enterprises were determined by this method. Results:: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection and quantitation were 0.06 ng/mL and 0.21 ng/mL, respectively. The average recovery was 98.62%, and the RSD was 4.31%. All batches of enteric capsules met the requirements; 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. Conclusion:: The presented method is sensitive, accurate, precise, and available for both enteric capsules and sustained-release tablets of metformin hydrochloride, which can provide a reference for their quality control. The over-limit phenomenon of NDMA in metformin hydrochloride products poses new challenges and requirements for both the State Drug Administration and enterprises. result: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection was 0.21 ng/mL. The average recovery was 98.62 %, and the RSD was 4.31%. All batches of enteric capsules met the requirements, 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. other: nothing","PeriodicalId":10889,"journal":{"name":"Current Pharmaceutical Analysis","volume":"16 1","pages":"0"},"PeriodicalIF":0.7000,"publicationDate":"2023-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/0115734129250659230929105800","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background:: N-nitrosodimethylamine (NDMA) are a sort of genotoxic impurities (GTIs) having strong carcinogenic effects and obvious hepatotoxicity. To monitor the NDMA content of metformin hydrochloride sustained-release tablets and enteric capsules in China from 2018 to 2022, a GC-MS/MS method was established and validated. background: N-nitrosodimethylamine (NDMA) is a sort of genotoxic impurities (GTIs) which has strong carcinogenic effect and obvious hepatotoxicity. To monitor NDMA content of in Metformin Hydrochloride Sustained-release Tablets and Enteric Capsules in China from 2018 to 2022, a GC-MS/MS method was established and verified. Methods:: The chromatographic column was Agilent VF-WAXms capillary column (30 m×0.25 mm, 0.25 μm). The GC-MS/MS method was equipped with multiple reaction monitoring (MRM) modes. To assess the quantity of NDMA, the molecular ion at mass-to-charge (m/z) of 74-44 was monitored under the 6 V collision energy, and to assess the quality of NDMA monitoring, the molecular ions at m/z 74-42 were determined. A total of 143 batches of metformin hydrochloride-finished products from 35 enterprises were determined by this method. Results:: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection and quantitation were 0.06 ng/mL and 0.21 ng/mL, respectively. The average recovery was 98.62%, and the RSD was 4.31%. All batches of enteric capsules met the requirements; 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. Conclusion:: The presented method is sensitive, accurate, precise, and available for both enteric capsules and sustained-release tablets of metformin hydrochloride, which can provide a reference for their quality control. The over-limit phenomenon of NDMA in metformin hydrochloride products poses new challenges and requirements for both the State Drug Administration and enterprises. result: The linear range of the method was 0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10, and the limit of detection was 0.21 ng/mL. The average recovery was 98.62 %, and the RSD was 4.31%. All batches of enteric capsules met the requirements, 38.21% of the 123 batches sustained-release tablets still exceeded the acceptable daily intake. other: nothing
方法采用GC-MS/MS法对国内盐酸二甲双胍产品中n -亚硝基二甲胺的含量进行验证和监测
背景:n -亚硝基二甲胺(NDMA)是一类具有强致癌性和明显肝毒性的遗传毒性杂质(GTIs)。为监测2018 - 2022年国内盐酸二甲双胍缓释片和肠溶胶囊中NDMA的含量,建立并验证了GC-MS/MS法。背景:n -亚硝基二甲胺(NDMA)是一种具有强致癌性和明显肝毒性的遗传毒性杂质(GTIs)。为监测2018 - 2022年国内盐酸二甲双胍缓释片和肠溶胶囊中NDMA的含量,建立并验证了GC-MS/MS法。方法:色谱柱为Agilent VF-WAXms毛细管柱(30 m×0.25 mm, 0.25 μm)。GC-MS/MS方法具有多种反应监测(MRM)模式。为了评估NDMA的数量,在6 V碰撞能量下监测74-44的质量电荷比(m/z)的分子离子,测定74-42的m/z的分子离子,以评估NDMA的监测质量。采用该方法对35家企业生产的143批盐酸二甲双胍成品进行了检测。结果:方法线性范围为0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10,检出限和定量限分别为0.06 ng/mL和0.21 ng/mL。平均加样回收率为98.62%,RSD为4.31%。所有批次肠溶胶囊均符合要求;123批缓释片中仍有38.21%超过可接受日摄入量。结论:本方法灵敏、准确、精密度高,适用于盐酸二甲双胍肠溶胶囊和缓释片,可为其质量控制提供参考。盐酸二甲双胍产品中NDMA的超标现象对国家药品监督管理局和企业提出了新的挑战和要求。结果:方法的线性范围为0.25 ~ 50.00 ng/mL, r = 0.9998, S/N>10,检出限为0.21 ng/mL。平均加样回收率为98.62%,RSD为4.31%。所有批次肠溶胶囊均符合要求,123批次缓释片中仍有38.21%超过日可接受摄入量。其他:无
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
85
审稿时长
3 months
期刊介绍: Aims & Scope Current Pharmaceutical Analysis publishes expert reviews and original research articles on all the most recent advances in pharmaceutical and biomedical analysis. All aspects of the field are represented including drug analysis, analytical methodology and instrumentation. The journal is essential to all involved in pharmaceutical, biochemical and clinical analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信