Post Occupancy Evaluation of Ventilation Coefficient Desired for Thermal Comfort in Educational Facilities

Emeka J. Mba, Francis O. Okeke, Emmanuel C. Ezema, Peter I. Oforji, Chinelo A. Ozigbo
{"title":"Post Occupancy Evaluation of Ventilation Coefficient Desired for Thermal Comfort in Educational Facilities","authors":"Emeka J. Mba, Francis O. Okeke, Emmanuel C. Ezema, Peter I. Oforji, Chinelo A. Ozigbo","doi":"10.28991/hef-2023-04-01-07","DOIUrl":null,"url":null,"abstract":"In tropical regions, one sustainable measure identified to attain thermal comfort and energy savings for interior spaces is natural ventilation. However, the ventilation coefficient as a factor for effective passive ventilation required for thermal comfort in educational facilities in warm, humid climates has not been adequately investigated. This study is a post-occupancy evaluation aimed at investigating the ventilation coefficient as a parameter for effective passive ventilation efficiency for good thermal comfort in the classrooms of public primary school buildings in Enugu Metropolis, Nigeria. Among the data collection instruments are two data logging devices (thermo-anemometers -AZ 9871) used to measure air velocity, humidity levels, and temperature outside and inside the classrooms of 60 government primary school buildings in the study area. This selection was based on stratified random sampling techniques. For data analysis, the global ventilation coefficient and linear regression analysis were used. The findings demonstrate that the average natural ventilation efficiency was 80%, which is higher than the global ventilation efficiency standard of 60%. The research results further highlight that colonial classroom prototype buildings have a lower temperature value and ventilation coefficient of 83%, which in turn influenced the thermal comfort conditions of the classrooms investigated. The significance of this study is that the findings contribute to the existing knowledge base that would advance strategic policy formation towards acceleration of the uptake of sustainable and energy-efficient building designs for educational facilities in warm, humid tropical environments. Doi: 10.28991/HEF-2023-04-01-07 Full Text: PDF","PeriodicalId":500209,"journal":{"name":"Journal of Human, Earth, and Future","volume":"131 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Human, Earth, and Future","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.28991/hef-2023-04-01-07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In tropical regions, one sustainable measure identified to attain thermal comfort and energy savings for interior spaces is natural ventilation. However, the ventilation coefficient as a factor for effective passive ventilation required for thermal comfort in educational facilities in warm, humid climates has not been adequately investigated. This study is a post-occupancy evaluation aimed at investigating the ventilation coefficient as a parameter for effective passive ventilation efficiency for good thermal comfort in the classrooms of public primary school buildings in Enugu Metropolis, Nigeria. Among the data collection instruments are two data logging devices (thermo-anemometers -AZ 9871) used to measure air velocity, humidity levels, and temperature outside and inside the classrooms of 60 government primary school buildings in the study area. This selection was based on stratified random sampling techniques. For data analysis, the global ventilation coefficient and linear regression analysis were used. The findings demonstrate that the average natural ventilation efficiency was 80%, which is higher than the global ventilation efficiency standard of 60%. The research results further highlight that colonial classroom prototype buildings have a lower temperature value and ventilation coefficient of 83%, which in turn influenced the thermal comfort conditions of the classrooms investigated. The significance of this study is that the findings contribute to the existing knowledge base that would advance strategic policy formation towards acceleration of the uptake of sustainable and energy-efficient building designs for educational facilities in warm, humid tropical environments. Doi: 10.28991/HEF-2023-04-01-07 Full Text: PDF
教育设施热舒适通风系数的使用后评价
在热带地区,一种可持续的措施被确定为实现热舒适和节能的室内空间是自然通风。然而,在温暖潮湿的气候条件下,通风系数作为教育设施热舒适所需的有效被动通风因素尚未得到充分的研究。本研究是一项使用后评价,旨在研究通风系数作为尼日利亚埃努古大都市公立小学教室有效被动通风效率的参数,以获得良好的热舒适。数据采集仪器中有两台数据记录设备(热风速计-AZ 9871),用于测量研究区60所公设小学教室内外的空气流速、湿度水平和温度。这种选择是基于分层随机抽样技术。数据分析采用整体通风系数和线性回归分析。研究结果表明,平均自然通风效率为80%,高于60%的全球通风效率标准。研究结果进一步强调,殖民地教室原型建筑的温值和通风系数较低,为83%,这反过来影响了所调查教室的热舒适条件。这项研究的重要意义在于,研究结果有助于现有的知识基础,这将推动战略政策的形成,以加速在温暖潮湿的热带环境中为教育设施采用可持续和节能的建筑设计。Doi: 10.28991/HEF-2023-04-01-07全文:PDF
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信