{"title":"Temporal bone phantom for decoupled cochlear implant electrode insertion force measurement","authors":"Jakob Cramer, Niklas Dassow, Georg Böttcher-Rebmann, Thomas Lenarz, Thomas S. Rau, Leon Budde","doi":"10.1515/cdbme-2023-1033","DOIUrl":null,"url":null,"abstract":"Abstract In research on cochlear implants, preclinical testing of newly developed electrode arrays and surgical tools is an essential procedure, which requires the availability of a suitable testing environment. For this purpose, human temporal bone specimens are most realistic, but their availability is limited and additional parameters such as insertion forces are hardly measurable. Therefore, the aim of this study was to develop a temporal bone phantom with realistic anatomical structures for intracochlear force measurement. The temporal bone was segmented from CBCT data of a human cadaver head. The segmented model was 3D printed with an additional artificial skin layer to enable the simulated use of surgical instruments such as a self-retaining retractor. A mechanically decoupled artificial cochlear model was realistically positioned within the temporal bone and was furthermore attached to a force sensor. The usability of the phantom was evaluated by performing automated EA insertions using an automated hydraulic insertion device. The experiments showed that the insertion forces within the cochlea could be measured without interferences from surrounding structures. Moreover, the artificial skin provided a rigid interface for the insertion tool. The new phantom is a realistic testing and training platform for cochlear implant electrode insertions with the advantage of measureable insertion forces.","PeriodicalId":10739,"journal":{"name":"Current Directions in Biomedical Engineering","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Directions in Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cdbme-2023-1033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract In research on cochlear implants, preclinical testing of newly developed electrode arrays and surgical tools is an essential procedure, which requires the availability of a suitable testing environment. For this purpose, human temporal bone specimens are most realistic, but their availability is limited and additional parameters such as insertion forces are hardly measurable. Therefore, the aim of this study was to develop a temporal bone phantom with realistic anatomical structures for intracochlear force measurement. The temporal bone was segmented from CBCT data of a human cadaver head. The segmented model was 3D printed with an additional artificial skin layer to enable the simulated use of surgical instruments such as a self-retaining retractor. A mechanically decoupled artificial cochlear model was realistically positioned within the temporal bone and was furthermore attached to a force sensor. The usability of the phantom was evaluated by performing automated EA insertions using an automated hydraulic insertion device. The experiments showed that the insertion forces within the cochlea could be measured without interferences from surrounding structures. Moreover, the artificial skin provided a rigid interface for the insertion tool. The new phantom is a realistic testing and training platform for cochlear implant electrode insertions with the advantage of measureable insertion forces.
解耦人工耳蜗电极插入力测量的颞骨模体
摘要在人工耳蜗的研究中,新开发的电极阵列和手术工具的临床前测试是必不可少的步骤,这需要一个合适的测试环境。为此,人类颞骨标本是最真实的,但它们的可用性有限,并且插入力等附加参数难以测量。因此,本研究的目的是开发具有真实解剖结构的颞骨假体,用于测量耳蜗内力。从人尸体头部的CBCT数据中分割颞骨。该分割模型是3D打印的,带有额外的人造皮肤层,以模拟使用手术器械,如自固定牵开器。将机械解耦人工耳蜗模型置入颞骨内,并与力传感器连接。通过使用自动液压插入装置进行自动EA插入来评估假体的可用性。实验表明,可以在不受周围结构干扰的情况下测量耳蜗内的插入力。此外,人造皮肤为插入工具提供了刚性界面。该假体具有插入力可测的优点,是人工耳蜗植入电极的真实测试和训练平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Current Directions in Biomedical Engineering
Current Directions in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
0.90
自引率
0.00%
发文量
239
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信