Serum Chromium is Inversely Correlated with the Carotid Intima– Media Thickness in Type 2 Diabetic Subjects

Fatima Qureshi, Haji Khan Khoharo
{"title":"Serum Chromium is Inversely Correlated with the Carotid Intima– Media Thickness in Type 2 Diabetic Subjects","authors":"Fatima Qureshi, Haji Khan Khoharo","doi":"10.18502/ijdo.v15i3.13738","DOIUrl":null,"url":null,"abstract":"Objective: The aim of this study was to determine and correlate the serum chromium in Carotid intima - media thickness (CIMT) in type 2 Diabetes Mellitus (T2DM) subjects.&#x0D; Materials and Methods: The present case – control study included 40 healthy controls and 45 T2DM subjects that were selected through non-probability (purposive) sampling by prior inclusion and exclusion criteria. Serum chromium (Cr) was detected and measured on inductively coupled “Plasma Optical Emission Spectrophotometer” (ICP- OES)- Carotid artery was examined with a 7.5-MHz linear-array transducer (Siemens Acuson x300) sonography. Data was analyzed by Student’s t test and Chi square test in the SPSS 22.0 (USA). Linear regression model was used for predicting carotid intima media thickness. Level of confidence interval of statistical significance was 95% (P≤ 0.05).&#x0D; Results: Serum Cr in controls and cases was noted 0.873 (± 0.162) and 0.281 (± 0.240) µg/ml (P= 0.001). Serum Cr proved negative correlation with random blood sugar (r= -0.145, P= 0.185), HbA1c (r= -0.145, P= 0.0001) and CIMT (r= -0.730, P= 0.0001). Multiple regression analysis model showed significant association of serum Cr (r= -0.730, P< 0.0001) and HbA1c (r= 0.754, P< 0.0001) with the CIMT.&#x0D; Conclusion: The present study reported serum Cr was inversely correlated with the carotid intima - media thickness that is a marker of atherosclerosis. Cr supplements may be advised to diabetics in clinical management.","PeriodicalId":33205,"journal":{"name":"Iranian Journal of Diabetes and Obesity","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Diabetes and Obesity","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/ijdo.v15i3.13738","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of this study was to determine and correlate the serum chromium in Carotid intima - media thickness (CIMT) in type 2 Diabetes Mellitus (T2DM) subjects. Materials and Methods: The present case – control study included 40 healthy controls and 45 T2DM subjects that were selected through non-probability (purposive) sampling by prior inclusion and exclusion criteria. Serum chromium (Cr) was detected and measured on inductively coupled “Plasma Optical Emission Spectrophotometer” (ICP- OES)- Carotid artery was examined with a 7.5-MHz linear-array transducer (Siemens Acuson x300) sonography. Data was analyzed by Student’s t test and Chi square test in the SPSS 22.0 (USA). Linear regression model was used for predicting carotid intima media thickness. Level of confidence interval of statistical significance was 95% (P≤ 0.05). Results: Serum Cr in controls and cases was noted 0.873 (± 0.162) and 0.281 (± 0.240) µg/ml (P= 0.001). Serum Cr proved negative correlation with random blood sugar (r= -0.145, P= 0.185), HbA1c (r= -0.145, P= 0.0001) and CIMT (r= -0.730, P= 0.0001). Multiple regression analysis model showed significant association of serum Cr (r= -0.730, P< 0.0001) and HbA1c (r= 0.754, P< 0.0001) with the CIMT. Conclusion: The present study reported serum Cr was inversely correlated with the carotid intima - media thickness that is a marker of atherosclerosis. Cr supplements may be advised to diabetics in clinical management.
2型糖尿病患者血清铬与颈动脉内膜-中膜厚度呈负相关
目的:本研究的目的是测定2型糖尿病(T2DM)患者颈动脉内膜-中膜厚度(CIMT)的血清铬含量并与之相关。材料与方法:本病例对照研究采用非概率(目的)抽样方法,采用预先纳入和排除标准,选取40名健康对照者和45名T2DM受试者。采用电感耦合“等离子体光学发射分光光度计”(ICP- OES)检测血清铬(Cr),用7.5 mhz线性阵列换能器(Siemens Acuson x300)超声检查颈动脉。数据分析采用SPSS 22.0(美国)的Student’s t检验和卡方检验。采用线性回归模型预测颈动脉内膜中膜厚度。统计学显著性置信区间为95% (P≤0.05)。 结果:对照组和病例血清Cr分别为0.873(±0.162)和0.281(±0.240)µg/ml (P= 0.001)。血清Cr与随机血糖(r= -0.145, P= 0.185)、糖化血红蛋白(r= -0.145, P= 0.0001)、CIMT (r= -0.730, P= 0.0001)呈负相关。多元回归分析模型显示,血清Cr与血清Cr显著相关(r= -0.730, P<0.0001)和HbA1c (r= 0.754, P<0.0001)与CIMT. 结论:本研究报道血清Cr与颈动脉内膜-中膜厚度呈负相关,颈动脉内膜-中膜厚度是动脉粥样硬化的标志。临床管理中建议糖尿病患者补充铬。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
25
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信