Functional measurements on carboxymethylated hemoglobin, a potential blood substitute: effects of sodium chloride on pH values that influence the alkaline Bohr effect.
{"title":"Functional measurements on carboxymethylated hemoglobin, a potential blood substitute: effects of sodium chloride on pH values that influence the alkaline Bohr effect.","authors":"L R Manning, W J Fantl, J M Manning","doi":"10.3109/10731199009117296","DOIUrl":null,"url":null,"abstract":"<p><p>The leakage of chloride from electrodes during measurements of the alkaline Bohr effect of hemoglobin (by the proton release method) amounted to 1-5 mM concentration of the anion depending on the type of electrode employed. This concentration, together with the amount of chloride found to be intrinsically bound to hemoglobin (0.2-0.6 mM), could mask the contribution of chloride to various hemoglobin functions. In addition, the concentration of chloride was found to affect the pH of buffers as measured either with a pH meter or with the dye, cresol red. Thus, for 20 mM phosphate buffer, the pH was lowered almost 0.4 pH units in the presence of 0.30 M chloride. For Tris-acetate buffer, the same concentration of chloride led to an increase in pH of about 0.05 units.</p>","PeriodicalId":77498,"journal":{"name":"Biomaterials, artificial cells, and artificial organs","volume":"18 2","pages":"133-41"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731199009117296","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterials, artificial cells, and artificial organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731199009117296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
The leakage of chloride from electrodes during measurements of the alkaline Bohr effect of hemoglobin (by the proton release method) amounted to 1-5 mM concentration of the anion depending on the type of electrode employed. This concentration, together with the amount of chloride found to be intrinsically bound to hemoglobin (0.2-0.6 mM), could mask the contribution of chloride to various hemoglobin functions. In addition, the concentration of chloride was found to affect the pH of buffers as measured either with a pH meter or with the dye, cresol red. Thus, for 20 mM phosphate buffer, the pH was lowered almost 0.4 pH units in the presence of 0.30 M chloride. For Tris-acetate buffer, the same concentration of chloride led to an increase in pH of about 0.05 units.