Highly sensitive zero-order emission system - fluorescence detection-liquid chromatographic method for simultaneous estimation of two banned phenyl xanthene dyes in bottled chili sauce
{"title":"Highly sensitive zero-order emission system - fluorescence detection-liquid chromatographic method for simultaneous estimation of two banned phenyl xanthene dyes in bottled chili sauce","authors":"Hazim M. Ali","doi":"10.4314/bcse.v37i6.2","DOIUrl":null,"url":null,"abstract":"ABSTRACT. A zero-order emission system was applied to address the variation in emission wavelengths between analytes. Also, it assists to compensate for the drop in emission intensity resulted from the changes in analyte excitation wavelength. So, a high performance liquid chromatography-fluorescence detector (HPLC-FLD) with zero order emission mode was used for the simultaneous estimation of rhodamine B (RhB) and eosin Y (EsY) based on their native fluorescence. The presented method is considered the first fluorescence method for simultaneous determination of RhB and EsY. The efficiency of the developed method was tested by determining the two dyes in a high matrix sample, chili sauce. Under the optimum condition, a linear calibration graphs for RhB and EsY in range of 0.5 -300 ng/mL with r = 0.9994 and 0.9991, respectively, were acquired. The limits of detection for RhB and EsY were 0.344 ng/mL (0.355 ng/g) and 0.215 ng/mL (0.222 ng/g), respectively. The recovery percentage and relative standard deviation of two analytes were obtained in the range of 98.38-101.86% and 0.83-1.66%, respectively. RhB was detected only in one chili sauce sample at a concentration of 0.388 ng/mL while EsY was not found in any sample.
 KEY WORDS: Rhodamine B, Eosin Y, HPLC-FLD, Zero-order emission mode, Solid phase extraction
 Bull. Chem. Soc. Ethiop. 2023, 37(6), 1315-1323. DOI: https://dx.doi.org/10.4314/bcse.v37i6.2","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/bcse.v37i6.2","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
ABSTRACT. A zero-order emission system was applied to address the variation in emission wavelengths between analytes. Also, it assists to compensate for the drop in emission intensity resulted from the changes in analyte excitation wavelength. So, a high performance liquid chromatography-fluorescence detector (HPLC-FLD) with zero order emission mode was used for the simultaneous estimation of rhodamine B (RhB) and eosin Y (EsY) based on their native fluorescence. The presented method is considered the first fluorescence method for simultaneous determination of RhB and EsY. The efficiency of the developed method was tested by determining the two dyes in a high matrix sample, chili sauce. Under the optimum condition, a linear calibration graphs for RhB and EsY in range of 0.5 -300 ng/mL with r = 0.9994 and 0.9991, respectively, were acquired. The limits of detection for RhB and EsY were 0.344 ng/mL (0.355 ng/g) and 0.215 ng/mL (0.222 ng/g), respectively. The recovery percentage and relative standard deviation of two analytes were obtained in the range of 98.38-101.86% and 0.83-1.66%, respectively. RhB was detected only in one chili sauce sample at a concentration of 0.388 ng/mL while EsY was not found in any sample.
KEY WORDS: Rhodamine B, Eosin Y, HPLC-FLD, Zero-order emission mode, Solid phase extraction
Bull. Chem. Soc. Ethiop. 2023, 37(6), 1315-1323. DOI: https://dx.doi.org/10.4314/bcse.v37i6.2
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.