Failure to Adjust CT Scanners to Pediatric Settings is a Major Cause of Unnecessary Radiation Exposure to Children

Jianna J. Lin, Jeremy Zhang, Lucille Anzia, Laura L. Hayes
{"title":"Failure to Adjust CT Scanners to Pediatric Settings is a Major Cause of Unnecessary Radiation Exposure to Children","authors":"Jianna J. Lin, Jeremy Zhang, Lucille Anzia, Laura L. Hayes","doi":"10.26502/jppch.74050166","DOIUrl":null,"url":null,"abstract":"CT scans are an indispensable tool for evaluating head injuries and neurological symptoms, yet they are the leading contributor to medical radiation exposure in the United States. High levels of such exposure pose significant health risks for children, whose developing bodies are less resilient to radiation injury. Here we review mean radiation dose (Total Exam DLP) and CTDlvol from head CT scans of 149 cases to assess for factors thought to be potential contributors to excess radiation exposure. Such factors included scan indication (trauma, shunts, other head complaints), number of repeat scans, and the type of facility the scan was performed (adult vs. pediatric). Analyses revealed that among scans performed to evaluate head trauma or routine indications (e.g. headache, vomiting focal neurologic deficits), the mean radiation dose a administered was significantly higher in adults hospitals when compared to pediatric hospitals. Findings highlight the importance of ensuring appropriate dose settings to increase the safety of CT scans for children. Based on our results identifying suboptimal scanner settings as a fundamental cause of excess radiation exposure, the evidence supports adjusting protocols to appropriate settings as the most effective method of reducing excess radiation exposure to children receiving head CT scans.","PeriodicalId":73894,"journal":{"name":"Journal of pediatrics, perinatology and child health","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pediatrics, perinatology and child health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26502/jppch.74050166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

CT scans are an indispensable tool for evaluating head injuries and neurological symptoms, yet they are the leading contributor to medical radiation exposure in the United States. High levels of such exposure pose significant health risks for children, whose developing bodies are less resilient to radiation injury. Here we review mean radiation dose (Total Exam DLP) and CTDlvol from head CT scans of 149 cases to assess for factors thought to be potential contributors to excess radiation exposure. Such factors included scan indication (trauma, shunts, other head complaints), number of repeat scans, and the type of facility the scan was performed (adult vs. pediatric). Analyses revealed that among scans performed to evaluate head trauma or routine indications (e.g. headache, vomiting focal neurologic deficits), the mean radiation dose a administered was significantly higher in adults hospitals when compared to pediatric hospitals. Findings highlight the importance of ensuring appropriate dose settings to increase the safety of CT scans for children. Based on our results identifying suboptimal scanner settings as a fundamental cause of excess radiation exposure, the evidence supports adjusting protocols to appropriate settings as the most effective method of reducing excess radiation exposure to children receiving head CT scans.
未能将CT扫描仪调整为儿童设置是儿童不必要辐射暴露的主要原因
CT扫描是评估头部损伤和神经系统症状不可或缺的工具,但在美国,它们是医疗辐射暴露的主要来源。高水平的辐射对儿童的健康构成重大威胁,因为儿童发育中的身体对辐射伤害的抵抗力较弱。在这里,我们回顾了149例头部CT扫描的平均辐射剂量(Total Exam DLP)和CTDlvol,以评估被认为是过量辐射暴露的潜在因素。这些因素包括扫描指征(创伤、分流、其他头部疾病)、重复扫描次数和扫描设备类型(成人与儿童)。分析显示,在评估头部创伤或常规适应症(如头痛、呕吐、局灶性神经功能缺陷)的扫描中,成人医院的平均辐射剂量明显高于儿科医院。研究结果强调了确保适当剂量设置以提高儿童CT扫描安全性的重要性。基于我们的研究结果,确定了不理想的扫描仪设置是过量辐射暴露的根本原因,证据支持调整方案到适当的设置是减少接受头部CT扫描的儿童过量辐射暴露的最有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信