{"title":"Study on the design of single-seat control valve with stable flow regulation and its fluid flow characteristics and thermal stress","authors":"Ruiming Yu , Yunyan Ma , Kuaile Liu , Xiangyu Liu","doi":"10.1016/j.flowmeasinst.2023.102486","DOIUrl":null,"url":null,"abstract":"<div><p>Aiming at technical problems such as unstable flow at small openings and uneven force on the valve core, the single-seat control valve with stable flow regulation is researched and designed. The tapered surface of the outer edge of the valve core can cooperate with the valve seat when the valve core is running stably, resulting in higher flow regulation accuracy and more stable regulation. The mechanical characteristics and flow characteristics are analyzed. The fluid flow simulation analyzes the pressure, velocity, density, mass flow rate and volume flow rate of the fluid under small and large openings of the single-seat control valve. The relationship between the maximum pressure, maximum velocity, maximum density, mass flow rate and volume flow rate of the inlet and outlet with the opening are analyzed from small opening to large opening and smaller opening. The spool motion simulation analyzes the relationship between actuator driving force, unbalanced force, linear displacement, velocity and acceleration with time. The thermal stress simulation analyzes the thermal temperature, resultant heat flow, thermal stress, thermal strain and safety factor, and the material strength meets the requirements. The valve body pressure test, valve seat sealing test, full stroke and switching time test, drift and jitter test, starting deviation test, basic error and return difference test and dead zone test are carried out on the single-seat control valve. The test results all meet the requirements. The simulation results are compared and analyzed with the test results, and the simulation results are consistent with the test result.</p></div>","PeriodicalId":50440,"journal":{"name":"Flow Measurement and Instrumentation","volume":"95 ","pages":"Article 102486"},"PeriodicalIF":2.3000,"publicationDate":"2023-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0955598623001826/pdfft?md5=3ef311bda028b0195933f2038b48095f&pid=1-s2.0-S0955598623001826-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flow Measurement and Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0955598623001826","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Aiming at technical problems such as unstable flow at small openings and uneven force on the valve core, the single-seat control valve with stable flow regulation is researched and designed. The tapered surface of the outer edge of the valve core can cooperate with the valve seat when the valve core is running stably, resulting in higher flow regulation accuracy and more stable regulation. The mechanical characteristics and flow characteristics are analyzed. The fluid flow simulation analyzes the pressure, velocity, density, mass flow rate and volume flow rate of the fluid under small and large openings of the single-seat control valve. The relationship between the maximum pressure, maximum velocity, maximum density, mass flow rate and volume flow rate of the inlet and outlet with the opening are analyzed from small opening to large opening and smaller opening. The spool motion simulation analyzes the relationship between actuator driving force, unbalanced force, linear displacement, velocity and acceleration with time. The thermal stress simulation analyzes the thermal temperature, resultant heat flow, thermal stress, thermal strain and safety factor, and the material strength meets the requirements. The valve body pressure test, valve seat sealing test, full stroke and switching time test, drift and jitter test, starting deviation test, basic error and return difference test and dead zone test are carried out on the single-seat control valve. The test results all meet the requirements. The simulation results are compared and analyzed with the test results, and the simulation results are consistent with the test result.
期刊介绍:
Flow Measurement and Instrumentation is dedicated to disseminating the latest research results on all aspects of flow measurement, in both closed conduits and open channels. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor, the fluid flow and the sensor/fluid interactions through the use of computation techniques; the development of advanced transducer systems and their associated signal processing and the laboratory and field assessment of the overall system under ideal and disturbed conditions.
FMI is the essential forum for critical information exchange, and contributions are particularly encouraged in the following areas of interest:
Modelling: the application of mathematical and computational modelling to the interaction of fluid dynamics with flowmeters, including flowmeter behaviour, improved flowmeter design and installation problems. Application of CAD/CAE techniques to flowmeter modelling are eligible.
Design and development: the detailed design of the flowmeter head and/or signal processing aspects of novel flowmeters. Emphasis is given to papers identifying new sensor configurations, multisensor flow measurement systems, non-intrusive flow metering techniques and the application of microelectronic techniques in smart or intelligent systems.
Calibration techniques: including descriptions of new or existing calibration facilities and techniques, calibration data from different flowmeter types, and calibration intercomparison data from different laboratories.
Installation effect data: dealing with the effects of non-ideal flow conditions on flowmeters. Papers combining a theoretical understanding of flowmeter behaviour with experimental work are particularly welcome.