Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
eJournal of Oral Maxillofacial Research Pub Date : 2023-09-30 eCollection Date: 2023-07-01 DOI:10.5037/jomr.2023.14302
Julia Olander, Sargon Barkarmo, Petra Hammarström Johansson, Ann Wennerberg, Victoria Franke Stenport
{"title":"Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients.","authors":"Julia Olander, Sargon Barkarmo, Petra Hammarström Johansson, Ann Wennerberg, Victoria Franke Stenport","doi":"10.5037/jomr.2023.14302","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads.</p><p><strong>Material and methods: </strong>Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads.</p><p><strong>Results: </strong>In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP - MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group.</p><p><strong>Conclusions: </strong>Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.</p>","PeriodicalId":53254,"journal":{"name":"eJournal of Oral Maxillofacial Research","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10645473/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"eJournal of Oral Maxillofacial Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5037/jomr.2023.14302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads.

Material and methods: Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads.

Results: In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP - MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group.

Conclusions: Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.

9例患者种植体周围粘膜炎症基因谱和颗粒存在的初步研究。
目的:本初步研究的目的是比较氧化锆基牙和钛基牙种植体周围粘膜的基因表达,并研究粘膜样品和种植体头部中颗粒的存在。材料与方法:选取10例使用单种植体支撑假体连接氧化锆或钛基牙的患者作为5年对照。进行了临床检查和功能外观经验调查。通过实时聚合酶链反应(qPCR)和扫描电子显微镜/能量色散x射线光谱仪(SEM/EDX)分析在种植体附近的粘膜活检。收集细胞学涂片样本,并通过电感耦合等离子体质谱(ICP-MS)分析,以调查颗粒在植入头的存在。结果:共有9例患者参与研究,其中钛基牙5例,氧化锆基牙4例。所有患者功能及美观均满意。粘膜活检检出钛、铁颗粒。ICP - MS分析证实了氧化锆和钛的存在。氧化锆基牙组多个促炎基因表达上调。结论:与钛基牙相比,氧化锆基牙周围的促炎反应和磨损颗粒的数量略有增加。钛的磨损颗粒存在于所有软组织样品中,而氧化锆颗粒仅存在于带有氧化锆基牙的种植体头部/粘膜样品中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
19
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信