Device malfunctions with use of EUS-guided fine-needle biopsy devices: Analysis of the MAUDE database.

IF 4.4 1区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY
Endoscopic Ultrasound Pub Date : 2023-09-01 Epub Date: 2023-08-12 DOI:10.1097/eus.0000000000000016
Achintya D Singh, Deepak Madhu, Mythili Menon Pathiyil, Daryl Ramai, Babu P Mohan, Bhavesh Shah, Douglas G Adler
{"title":"Device malfunctions with use of EUS-guided fine-needle biopsy devices: Analysis of the MAUDE database.","authors":"Achintya D Singh, Deepak Madhu, Mythili Menon Pathiyil, Daryl Ramai, Babu P Mohan, Bhavesh Shah, Douglas G Adler","doi":"10.1097/eus.0000000000000016","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The safety of endoscopic ultrasound-guided tissue acquisition through fine-needle biopsy devices is well-established in clinical trials. The real-world experience of using these devices is not known. The authors analyzed the postmarketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database to answer this question.</p><p><strong>Methods: </strong>The Food and Drug Administration MAUDE database from January 2012 to June 2022 was accessed to evaluate for device malfunctions and patient-related adverse consequences of these malfunctions.</p><p><strong>Results: </strong>There were 344 device-related issues. Most issues were due to detachment or breakage of the device (<i>n</i> = 185 [53.7%]). Seventy-six of the breakages (40.8%) occurred during the procedure, whereas 89 cases (47.8%) occurred while removing the needle from the endoscope. The most common site of tissue biopsy at the time of needle breakage was the pancreas (44 [23.8%]).The common patient-related adverse events were retained foreign body (<i>n</i> = 50 [14.5%]) followed by bleeding (16, 4.6%). Six patients (3.4%) required a second intervention for removal of the retained foreign bodies including surgery in 2 cases. The device breakage damaged the endoscope in 3 cases (1.7%), and there was 1 case of needlestick injury to the nurse.</p><p><strong>Conclusion: </strong>The fine-needle biopsy devices can be associated with needle breakage and bending; these adverse events were not previously reported. Needle breakages can result in a retained foreign body that may require additional procedures including surgery. These real-world findings from the MAUDE database may inform clinical decisions and help improve clinical outcomes.</p>","PeriodicalId":11577,"journal":{"name":"Endoscopic Ultrasound","volume":"12 5","pages":"424-427"},"PeriodicalIF":4.4000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10631607/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopic Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/eus.0000000000000016","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The safety of endoscopic ultrasound-guided tissue acquisition through fine-needle biopsy devices is well-established in clinical trials. The real-world experience of using these devices is not known. The authors analyzed the postmarketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database to answer this question.

Methods: The Food and Drug Administration MAUDE database from January 2012 to June 2022 was accessed to evaluate for device malfunctions and patient-related adverse consequences of these malfunctions.

Results: There were 344 device-related issues. Most issues were due to detachment or breakage of the device (n = 185 [53.7%]). Seventy-six of the breakages (40.8%) occurred during the procedure, whereas 89 cases (47.8%) occurred while removing the needle from the endoscope. The most common site of tissue biopsy at the time of needle breakage was the pancreas (44 [23.8%]).The common patient-related adverse events were retained foreign body (n = 50 [14.5%]) followed by bleeding (16, 4.6%). Six patients (3.4%) required a second intervention for removal of the retained foreign bodies including surgery in 2 cases. The device breakage damaged the endoscope in 3 cases (1.7%), and there was 1 case of needlestick injury to the nurse.

Conclusion: The fine-needle biopsy devices can be associated with needle breakage and bending; these adverse events were not previously reported. Needle breakages can result in a retained foreign body that may require additional procedures including surgery. These real-world findings from the MAUDE database may inform clinical decisions and help improve clinical outcomes.

使用eus引导的细针活检设备的设备故障:MAUDE数据库的分析。
背景:超声内镜引导下通过细针活检装置获取组织的安全性在临床试验中得到了证实。使用这些设备的真实体验尚不清楚。作者分析了食品和药物管理局制造商和用户设施设备体验(MAUDE)数据库中的上市后监测数据来回答这个问题。方法:访问2012年1月至2022年6月美国食品药品监督管理局MAUDE数据库,评估设备故障和这些故障与患者相关的不良后果。结果:共发现344例器械相关问题。大多数问题是由于器械脱离或断裂(n = 185[53.7%])。76例(40.8%)发生在手术过程中,89例(47.8%)发生在从内窥镜取出针头时。破针时最常见的组织活检部位为胰腺(44例[23.8%])。常见的患者相关不良事件为异物潴留(n = 50[14.5%]),其次为出血(16,4.6%)。6例(3.4%)患者需要第二次干预去除残留的异物,包括2例手术。器械破损损坏内窥镜3例(1.7%),护士被刺伤1例。结论:细针活检装置可伴有针头断裂和弯曲;这些不良事件以前未见报道。针头断裂可能导致异物残留,这可能需要额外的治疗,包括手术。这些来自MAUDE数据库的真实世界的发现可以为临床决策提供信息,并有助于改善临床结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Endoscopic Ultrasound
Endoscopic Ultrasound GASTROENTEROLOGY & HEPATOLOGY-
CiteScore
6.20
自引率
11.10%
发文量
144
期刊介绍: Endoscopic Ultrasound, a publication of Euro-EUS Scientific Committee, Asia-Pacific EUS Task Force and Latin American Chapter of EUS, is a peer-reviewed online journal with Quarterly print on demand compilation of issues published. The journal’s full text is available online at http://www.eusjournal.com. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository. The journal does not charge for submission, processing or publication of manuscripts and even for color reproduction of photographs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信