{"title":"Compact anechoic chamber for immunity test and EMI noise measurement","authors":"K. Ishino, Y. Hashimoto, M. Okamura, Y. Shimizu","doi":"10.1109/ISEMC.1991.148271","DOIUrl":null,"url":null,"abstract":"The distribution of the electromagnetic field in the compact anechoic chamber consisting of four walls, ceiling, and floor with ferrite absorbing materials was investigated. The compact anechoic chamber used for both immunity test and electromagnetic interference (EMI) noise measurement was developed by improved ferrite absorber. The compact chamber was extremely uniform, and the maximum deviation is less than 6 dB in the vertical plane. The site attenuation characteristics in the compact chamber were in good agreement with those in the open-field test site.<<ETX>>","PeriodicalId":243730,"journal":{"name":"IEEE 1991 International Symposium on Electromagnetic Compatibility","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1991 International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1991.148271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The distribution of the electromagnetic field in the compact anechoic chamber consisting of four walls, ceiling, and floor with ferrite absorbing materials was investigated. The compact anechoic chamber used for both immunity test and electromagnetic interference (EMI) noise measurement was developed by improved ferrite absorber. The compact chamber was extremely uniform, and the maximum deviation is less than 6 dB in the vertical plane. The site attenuation characteristics in the compact chamber were in good agreement with those in the open-field test site.<>
用于抗扰度测试和电磁干扰噪声测量的紧凑型消声室
研究了由铁氧体吸波材料组成的四壁、顶板和底板的紧凑消声室的电磁场分布。采用改进的铁氧体吸波器,研制了一种既可用于抗扰度测试又可用于电磁干扰(EMI)噪声测量的小型消声室。压实腔非常均匀,在垂直方向上的最大偏差小于6 dB。压实室的场地衰减特性与露天试验场地的衰减特性吻合较好
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信