{"title":"Analysis of aquifers, humidity levels with geoelectric resistivity value, and NDW Index in the geothermal area of North Langowan","authors":"Bella M. Wowor, F. J. Manoppo, Herawaty Riogilang","doi":"10.35800/jasm.v9i2.35523","DOIUrl":null,"url":null,"abstract":"This research was conducted to examine the condition (location, depth, and thickness) of the aquifer, to assess the humidity level using the NDW index, and to determine the relationship between aquifer conditions and the sustainability of the geothermal system using the geoelectrical method of resistivity in the North Langowan geothermal area. The comparison between rock layer resistivity data and spectral values based on geological-hydrogeological maps was carried out to determine the relationship between aquifer conditions and humidity levels in the geothermal area to the continuity of the geothermal system in the Tompaso region. The data was processed using IP2WIN and ILWIS programs. The results showed that at the research site there were semi-confined aquifers and free aquifers, which were indicated by low resistivity values. It can be concluded that the aquifer in the North Langowan geothermal area was at a depth ranging from 0 m to 16 m with a thickness ranging from 3.98 to 12 m, moderate wetness, and has a good relationship in supporting the continuity of the Tompaso geothermal system.Indonesian title: Analisis akuifer, tingkat kelembaban dengan nilai resistivitas geolistrik, dan Index NDW di daerah panas bumi Langowan Utara","PeriodicalId":106687,"journal":{"name":"AQUATIC SCIENCE & MANAGEMENT","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AQUATIC SCIENCE & MANAGEMENT","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35800/jasm.v9i2.35523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This research was conducted to examine the condition (location, depth, and thickness) of the aquifer, to assess the humidity level using the NDW index, and to determine the relationship between aquifer conditions and the sustainability of the geothermal system using the geoelectrical method of resistivity in the North Langowan geothermal area. The comparison between rock layer resistivity data and spectral values based on geological-hydrogeological maps was carried out to determine the relationship between aquifer conditions and humidity levels in the geothermal area to the continuity of the geothermal system in the Tompaso region. The data was processed using IP2WIN and ILWIS programs. The results showed that at the research site there were semi-confined aquifers and free aquifers, which were indicated by low resistivity values. It can be concluded that the aquifer in the North Langowan geothermal area was at a depth ranging from 0 m to 16 m with a thickness ranging from 3.98 to 12 m, moderate wetness, and has a good relationship in supporting the continuity of the Tompaso geothermal system.Indonesian title: Analisis akuifer, tingkat kelembaban dengan nilai resistivitas geolistrik, dan Index NDW di daerah panas bumi Langowan Utara
研究了北朗古湾地热区含水层条件(位置、深度和厚度),利用NDW指数评价含水层湿度水平,并利用电阻率地电法确定含水层条件与地热系统可持续性的关系。通过对比地层电阻率数据和基于地质水文地质图的频谱值,确定了热区含水层条件和湿度水平与Tompaso地区地热系统连续性的关系。使用IP2WIN和ILWIS程序对数据进行处理。结果表明:研究点存在半承压含水层和自由含水层,以低电阻率值表示;结果表明,北朗古湾地热区含水层深度为0 ~ 16 m,厚度为3.98 ~ 12 m,湿度适中,与托姆帕索地热系统的连续性有较好的支撑关系。印尼语标题:分析akuifer, tingkat kelembaban dengan nilai resistivitas geoistk, dan Index NDW di daerah panas bumi langgowan Utara