Failure of a Cast Conveyor Chain Link

{"title":"Failure of a Cast Conveyor Chain Link","authors":"","doi":"10.31399/asm.fach.matlhand.c0047432","DOIUrl":null,"url":null,"abstract":"\n The conveyor chain link failed by fracturing through a fabrication weld after some time in service. The link was made of cast low-alloy steel heat treated to a hardness of 285 HRB. The fabrication weld was made using E7018 electrodes. The fracture surfaces were almost entirely covered with beach marks, indicating fatigue cracking. The beach marks emanated from a 6.4 mm (1/4 in.) wide band of unusual appearance running across the center of the fracture. Saw cuts were made perpendicular to both of the fracture surfaces and across the unusual-looking bands. The cut surfaces were ground and etched with ammonium persulfate solution revealing that complete penetration had not been achieved at the weld root. The band observed in the fracture was apparently part of the unfused weld-preparation surface at the root of the weld. This failure was caused by fatigue that initiated at an incomplete penetration defect at the root of the fabrication weld. As a result of this failure, steps were taken to ensure that good welding practice (back-gouging) would be followed in the future fabrication of these links.","PeriodicalId":131762,"journal":{"name":"ASM Failure Analysis Case Histories: Material Handling Equipment","volume":"438 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASM Failure Analysis Case Histories: Material Handling Equipment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.fach.matlhand.c0047432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The conveyor chain link failed by fracturing through a fabrication weld after some time in service. The link was made of cast low-alloy steel heat treated to a hardness of 285 HRB. The fabrication weld was made using E7018 electrodes. The fracture surfaces were almost entirely covered with beach marks, indicating fatigue cracking. The beach marks emanated from a 6.4 mm (1/4 in.) wide band of unusual appearance running across the center of the fracture. Saw cuts were made perpendicular to both of the fracture surfaces and across the unusual-looking bands. The cut surfaces were ground and etched with ammonium persulfate solution revealing that complete penetration had not been achieved at the weld root. The band observed in the fracture was apparently part of the unfused weld-preparation surface at the root of the weld. This failure was caused by fatigue that initiated at an incomplete penetration defect at the root of the fabrication weld. As a result of this failure, steps were taken to ensure that good welding practice (back-gouging) would be followed in the future fabrication of these links.
铸造输送机链环故障
输送链在使用一段时间后因制造焊缝破裂而失效。连杆采用热处理硬度为285 HRB的铸造低合金钢。加工焊缝采用E7018电极。断口表面几乎完全覆盖着海滩痕迹,表明疲劳开裂。海滩痕迹来自一个6.4毫米(1/4英寸)宽的不寻常的带,穿过骨折的中心。锯切垂直于两个断裂面,并穿过不寻常的带。用过硫酸铵溶液对切割表面进行研磨和蚀刻,发现焊缝根部没有完全渗透。断口处观察到的条带明显是焊缝根部未熔解的焊前表面的一部分。这种失效是由疲劳引起的,疲劳是由制造焊缝根部的不完全渗透缺陷引起的。由于这一失败,采取措施,以确保良好的焊接实践(反刨)将遵循这些链接的未来制造。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信