{"title":"Performance characteristics of a doubly-fed generator on a test-rig with full-scale converter-based grid emulator","authors":"Nurhan Rizqy Averous, H. Stagge, R. D. De Doncker","doi":"10.1109/PEMWA.2014.6912221","DOIUrl":null,"url":null,"abstract":"One key factor for a successfull penetration of wind turbine (WT) products into the market is certification. For the development and certification purpose, a 1 MW test-rig for WT nacelles has been developed at RWTH Aachen University which offers the possibility of WT testing with emulated environmental conditions. In this paper, the performance characteristics of a doubly-fed-generator (DFG) on the developed test-rig is discussed. Firstly, the effect of filter impedance of the grid emulator on the controller performance is analyzed under normal grid conditions. Secondly, the transient characteristic of a DFG WT considering the grid emulator setup is identified. A simulation is performed to verify the analysis. Under normal grid condition, the impedance of the grid emulator does not influence the controller of the DFG WT significantly. For fault-ride-through (FRT) tests with a grid emulator, only the series inductive elements of the grid emulator's filter influence the transient characteristic of the DFG WT. The developed 1-MW test-rig fulfills the technical requirement for FRT test in terms of the grid impedance.","PeriodicalId":370712,"journal":{"name":"2014 IEEE Symposium on Power Electronics and Machines for Wind and Water Applications","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Symposium on Power Electronics and Machines for Wind and Water Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEMWA.2014.6912221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
One key factor for a successfull penetration of wind turbine (WT) products into the market is certification. For the development and certification purpose, a 1 MW test-rig for WT nacelles has been developed at RWTH Aachen University which offers the possibility of WT testing with emulated environmental conditions. In this paper, the performance characteristics of a doubly-fed-generator (DFG) on the developed test-rig is discussed. Firstly, the effect of filter impedance of the grid emulator on the controller performance is analyzed under normal grid conditions. Secondly, the transient characteristic of a DFG WT considering the grid emulator setup is identified. A simulation is performed to verify the analysis. Under normal grid condition, the impedance of the grid emulator does not influence the controller of the DFG WT significantly. For fault-ride-through (FRT) tests with a grid emulator, only the series inductive elements of the grid emulator's filter influence the transient characteristic of the DFG WT. The developed 1-MW test-rig fulfills the technical requirement for FRT test in terms of the grid impedance.