{"title":"The Argo YBJ daq and trigger system","authors":"A. Budano","doi":"10.1109/RTC.2007.4382846","DOIUrl":null,"url":null,"abstract":"The Argo-YBJ experiment has now reached its final design configuration. The detector system consists of a full coverage array (about 5800 square meters) of resistive plate chambers (RPCs). The required throughput depends on the trigger rate and threshold. The DAQ system must be able to sustain a maximum transfer rate of the order of 15 MB/s and a high peak data flow. Data are read out using a typical front-end acquisition chain built around a custom bus. Specialized electronics have been designed and efficient software has been written to perform this task. Data are sent to the on line farm through a switch exploiting a gigabit ethernet protocol. A solution to transfer data from the YBJ laboratory to the laboratories belonging to the Argo-YBJ collaboration exploiting the GRID middleware has also been implemented. In this paper we describe the daq, the trigger environment and the data mover main characteristics and performances.","PeriodicalId":217483,"journal":{"name":"2007 15th IEEE-NPSS Real-Time Conference","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 15th IEEE-NPSS Real-Time Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTC.2007.4382846","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The Argo-YBJ experiment has now reached its final design configuration. The detector system consists of a full coverage array (about 5800 square meters) of resistive plate chambers (RPCs). The required throughput depends on the trigger rate and threshold. The DAQ system must be able to sustain a maximum transfer rate of the order of 15 MB/s and a high peak data flow. Data are read out using a typical front-end acquisition chain built around a custom bus. Specialized electronics have been designed and efficient software has been written to perform this task. Data are sent to the on line farm through a switch exploiting a gigabit ethernet protocol. A solution to transfer data from the YBJ laboratory to the laboratories belonging to the Argo-YBJ collaboration exploiting the GRID middleware has also been implemented. In this paper we describe the daq, the trigger environment and the data mover main characteristics and performances.