The exploitation of asymmetry in electric power transmission networks

A. Sana, R. Marceau, C. Todde, D. Do, J. Mahseredjian, G. Joós
{"title":"The exploitation of asymmetry in electric power transmission networks","authors":"A. Sana, R. Marceau, C. Todde, D. Do, J. Mahseredjian, G. Joós","doi":"10.1109/CCECE.1998.685539","DOIUrl":null,"url":null,"abstract":"For more than a century electric networks have evolved on the basis of a three phase symmetrical equilibrium system. If the current and voltage distortion is seen as inevitable in the daily exploitation, the philosophy basically remains the same: the three phases are considered as a single symmetric ensemble. In high, very high and ultra high voltage (HV, VHV, and UHV) the appearance of a contingency automatically carries out cutting of the three phase line into single, two or three phases all at once. But, having the same reaction vis-a-vis the whole, the case of faults is not optimal. In this article, we effect a revue of methods and criteria actually used in the assertion of security limits, we set out the concepts and basis of constraints binding the exploitation of a three phase line as three independent lines and discuss a realisable solution for the exploitation of a HV or VHV transmission network managing asymmetry and security.","PeriodicalId":177613,"journal":{"name":"Conference Proceedings. IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.98TH8341)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. IEEE Canadian Conference on Electrical and Computer Engineering (Cat. No.98TH8341)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE.1998.685539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For more than a century electric networks have evolved on the basis of a three phase symmetrical equilibrium system. If the current and voltage distortion is seen as inevitable in the daily exploitation, the philosophy basically remains the same: the three phases are considered as a single symmetric ensemble. In high, very high and ultra high voltage (HV, VHV, and UHV) the appearance of a contingency automatically carries out cutting of the three phase line into single, two or three phases all at once. But, having the same reaction vis-a-vis the whole, the case of faults is not optimal. In this article, we effect a revue of methods and criteria actually used in the assertion of security limits, we set out the concepts and basis of constraints binding the exploitation of a three phase line as three independent lines and discuss a realisable solution for the exploitation of a HV or VHV transmission network managing asymmetry and security.
电力传输网络中不对称性的利用
一个多世纪以来,电网是在三相对称平衡系统的基础上发展起来的。如果电流和电压失真在日常开发中被视为不可避免的,其原理基本保持不变:将三个阶段视为单个对称集合。在高压、甚高压和特高压(HV、VHV和UHV)中,偶发事件的出现会自动将三相线路一次切割成单相、两相或三相。但是,如果对整体有相同的反应,那么故障的情况就不是最佳的。在本文中,我们对安全限制断言中实际使用的方法和标准进行了评估,我们列出了约束三相线作为三条独立线路开发的概念和基础,并讨论了开发高压或甚高压传输网络管理不对称和安全的可行解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信