{"title":"Load voltage stabilization of noncontact energy transfer using three resonant circuit","authors":"H. Abe, H. Sakamoto, K. Harada","doi":"10.1109/PCC.2002.997563","DOIUrl":null,"url":null,"abstract":"This paper is related to the noncontact energy transfer system which can stabilize the load voltage with no feedback control used three resonant circuits. This system which employs a detachable transformer for magnetic coupling has a leakage inductance. Therefore load voltage decreases greatly in proportion to load electric current. A feedback control circuit of the noncontact energy transfer system is more complicated than that of the contact energy transfer system. Namely, a noncontact energy transfer system with no-feedback system is expected for stabilization of the load voltage. A high efficiency noncontact energy transfer system requires several resonant circuits such as resonant inverter and resonant circuit for load matching. The authors found a novel method which minimizes the load voltage drop rate by using optimized capacitance value of above the resonant circuits.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCC.2002.997563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
This paper is related to the noncontact energy transfer system which can stabilize the load voltage with no feedback control used three resonant circuits. This system which employs a detachable transformer for magnetic coupling has a leakage inductance. Therefore load voltage decreases greatly in proportion to load electric current. A feedback control circuit of the noncontact energy transfer system is more complicated than that of the contact energy transfer system. Namely, a noncontact energy transfer system with no-feedback system is expected for stabilization of the load voltage. A high efficiency noncontact energy transfer system requires several resonant circuits such as resonant inverter and resonant circuit for load matching. The authors found a novel method which minimizes the load voltage drop rate by using optimized capacitance value of above the resonant circuits.