Control Strategy of Delta-Connected Solid State Transformer Under Unbalanced Grid Voltage

Ouyang Shaodi
{"title":"Control Strategy of Delta-Connected Solid State Transformer Under Unbalanced Grid Voltage","authors":"Ouyang Shaodi","doi":"10.1109/APEC43599.2022.9773558","DOIUrl":null,"url":null,"abstract":"The Solid State Transformer (SST) or Power Electronic Transformer (PET) is a key technique in the future distribution grid. The mainstream selection of SST MV stage is cascaded H-bridge, but till now, researchers have not reached a conclusion on whether star-connected CHB or delta-connected CHB is better. This paper gives a comparison on input power capability of the two configurations under unbalanced grid voltage. The input current stress and operating range under unbalanced grid voltage of the two CHBs have been analyzed. A zero-sequence current injection algorithm is proposed to reduce the phase current stress of delta-connected PET which can increase its operation range. The analysis and control schemes are supported by both simulation and experimental.","PeriodicalId":127006,"journal":{"name":"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC43599.2022.9773558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Solid State Transformer (SST) or Power Electronic Transformer (PET) is a key technique in the future distribution grid. The mainstream selection of SST MV stage is cascaded H-bridge, but till now, researchers have not reached a conclusion on whether star-connected CHB or delta-connected CHB is better. This paper gives a comparison on input power capability of the two configurations under unbalanced grid voltage. The input current stress and operating range under unbalanced grid voltage of the two CHBs have been analyzed. A zero-sequence current injection algorithm is proposed to reduce the phase current stress of delta-connected PET which can increase its operation range. The analysis and control schemes are supported by both simulation and experimental.
电网电压不平衡条件下三角连接固态变压器的控制策略
固态变压器(SST)或电力电子变压器(PET)是未来配电网的关键技术。SST MV级的主流选择是级联h桥,但到目前为止,对于星型连接的CHB和delta型连接的CHB哪个更好,研究者还没有得出结论。本文比较了两种配置在电网电压不平衡情况下的输入功率能力。分析了两种CHBs在电网电压不平衡情况下的输入电流应力和工作范围。提出了一种零序电流注入算法,以减小三角连接PET的相电流应力,提高其工作范围。仿真和实验结果支持了分析和控制方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信