Limits of Detection Based on the Four-Parameter Logistic Model for E. coli Determined using a Fluorescent-based Sensor

S. N. Padrilah, N. A. Masdor
{"title":"Limits of Detection Based on the Four-Parameter Logistic Model for E. coli Determined using a Fluorescent-based Sensor","authors":"S. N. Padrilah, N. A. Masdor","doi":"10.54987/jemat.v9i1.596","DOIUrl":null,"url":null,"abstract":"\n \n \n \nBecause of the huge number of outbreaks, bacterial infection is becoming more common, which is compounded by the rise of antibiotic resistance. These issues have warranted the development of sensitive detection and therapeutic devices. A fluorescence-based detection of the pathogen E. coli is previously developed using a mini-emulsion technique to create fluorescent/electroactive poly(3-hexylthiophene) P3HT nanoparticles (NPs) stabilized with CTAB or cetyltrimethylammonium bromide, a quaternary ammonium salt forming CTAB-P3HT NPs. Limits of detection for the bacterium based on fluorescence spectroscopy is 5 CFU/mL. The curve showed a sigmoidal calibration curve but was not modelled according to any of the sigmoidal models available. The aim of this study is to use the Four-Parameter Logistic Model to determine the LOD value more accurately. The modelling exercise gave values of the parameters a, d, Log EC50 and Hillslope representing the maximum and minimum responses, value that produces a 50% signal response, and a slope-like parameter (Hill coefficient) of -0.01427 (DF/F0), 0.6189 (DF/F0), 3.473 and 0.413, respectively. The LOD value was 30 CFU/mL with the 95% confidence interval from 13 to 64 CFU/mL. The usage of the 4Pl model in this study was successful, since it was able to represent the entire date curve. The correlation coefficient values of 0.986 indicated good fitting of the experimental data to the 4PL model. The 4PL model has been found to be a good model in fitting the calibration curve for the detection of E. coli. \n \n \n \n","PeriodicalId":393012,"journal":{"name":"Journal of Environmental Microbiology and Toxicology","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Microbiology and Toxicology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54987/jemat.v9i1.596","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Because of the huge number of outbreaks, bacterial infection is becoming more common, which is compounded by the rise of antibiotic resistance. These issues have warranted the development of sensitive detection and therapeutic devices. A fluorescence-based detection of the pathogen E. coli is previously developed using a mini-emulsion technique to create fluorescent/electroactive poly(3-hexylthiophene) P3HT nanoparticles (NPs) stabilized with CTAB or cetyltrimethylammonium bromide, a quaternary ammonium salt forming CTAB-P3HT NPs. Limits of detection for the bacterium based on fluorescence spectroscopy is 5 CFU/mL. The curve showed a sigmoidal calibration curve but was not modelled according to any of the sigmoidal models available. The aim of this study is to use the Four-Parameter Logistic Model to determine the LOD value more accurately. The modelling exercise gave values of the parameters a, d, Log EC50 and Hillslope representing the maximum and minimum responses, value that produces a 50% signal response, and a slope-like parameter (Hill coefficient) of -0.01427 (DF/F0), 0.6189 (DF/F0), 3.473 and 0.413, respectively. The LOD value was 30 CFU/mL with the 95% confidence interval from 13 to 64 CFU/mL. The usage of the 4Pl model in this study was successful, since it was able to represent the entire date curve. The correlation coefficient values of 0.986 indicated good fitting of the experimental data to the 4PL model. The 4PL model has been found to be a good model in fitting the calibration curve for the detection of E. coli.
基于四参数Logistic模型的荧光传感器检测大肠杆菌的检出限
由于暴发数量巨大,细菌感染正变得越来越普遍,抗生素耐药性的上升使情况更加复杂。这些问题需要开发敏感的检测和治疗设备。以前开发了一种基于荧光的病原体大肠杆菌检测方法,使用微乳液技术创建荧光/电活性聚(3-己基噻吩)P3HT纳米颗粒(NPs),该纳米颗粒由CTAB或十六烷基三甲基溴化铵稳定,十六烷基三甲基溴化铵是形成CTAB-P3HT NPs的季铵盐。基于荧光光谱的细菌检出限为5 CFU/mL。曲线显示为s型校正曲线,但没有根据任何可用的s型模型建模。本研究的目的是利用四参数Logistic模型更准确地确定LOD值。建模过程给出了代表最大和最小响应的参数a、d、Log EC50和Hillslope的值,产生50%信号响应的值,以及类似斜坡的参数(Hill系数)分别为-0.01427 (DF/F0)、0.6189 (DF/F0)、3.473和0.413。LOD值为30 CFU/mL, 95%置信区间为13 ~ 64 CFU/mL。在本研究中,4Pl模型的使用是成功的,因为它能够表示整个日期曲线。相关系数为0.986,表明实验数据与4PL模型拟合良好。在拟合大肠杆菌检测的校准曲线时,发现4PL模型是一个很好的模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信