Christoph Weimer, Xiaodi Jin, G. Fischer, M. Schröter
{"title":"Characterization of Dynamic Large-Signal Operating Limits and Long-Term RF Reliability of SiGe HBTs","authors":"Christoph Weimer, Xiaodi Jin, G. Fischer, M. Schröter","doi":"10.1109/BCICTS53451.2022.10051735","DOIUrl":null,"url":null,"abstract":"The dynamic (RF) large-signal operating limits of advanced SiGe HBTs are systematically explored and discussed. Experimental results of long-term RF stress tests performed with a passive load-pull system are presented and analyzed. The experimental data demonstrate that SiGe HBTs are extremely robust and can be operated statically and dynamically far beyond the open-base collector-emitter breakdown voltage without noticeable degradation during the long stress times. The results suggest that only extremely non-linear large-signal operating conditions cause significant degradation of the admittance parameters. RF stress tests of HBTs with different emitter widths suggest that the measured degradation is area-related and can be attributed to the minority carrier charge storage and transport.","PeriodicalId":289208,"journal":{"name":"2022 IEEE BiCMOS and Compound Semiconductor Integrated Circuits and Technology Symposium (BCICTS)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE BiCMOS and Compound Semiconductor Integrated Circuits and Technology Symposium (BCICTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BCICTS53451.2022.10051735","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
The dynamic (RF) large-signal operating limits of advanced SiGe HBTs are systematically explored and discussed. Experimental results of long-term RF stress tests performed with a passive load-pull system are presented and analyzed. The experimental data demonstrate that SiGe HBTs are extremely robust and can be operated statically and dynamically far beyond the open-base collector-emitter breakdown voltage without noticeable degradation during the long stress times. The results suggest that only extremely non-linear large-signal operating conditions cause significant degradation of the admittance parameters. RF stress tests of HBTs with different emitter widths suggest that the measured degradation is area-related and can be attributed to the minority carrier charge storage and transport.