Compressive power spectrum sensing for vibration-based output-only system identification of structural systems in the presence of noise

Bamrung Tau Siesakul, K. Gkoktsi, A. Giaralis
{"title":"Compressive power spectrum sensing for vibration-based output-only system identification of structural systems in the presence of noise","authors":"Bamrung Tau Siesakul, K. Gkoktsi, A. Giaralis","doi":"10.1117/12.2177162","DOIUrl":null,"url":null,"abstract":"Motivated by the need to reduce monetary and energy consumption costs of wireless sensor networks in undertaking output-only/operational modal analysis of engineering structures, this paper considers a multi-coset analog-toinformation converter for structural system identification from acceleration response signals of white noise excited linear damped structures sampled at sub-Nyquist rates. The underlying natural frequencies, peak gains in the frequency domain, and critical damping ratios of the vibrating structures are estimated directly from the sub-Nyquist measurements and, therefore, the computationally demanding signal reconstruction step is by-passed. This is accomplished by first employing a power spectrum blind sampling (PSBS) technique for multi-band wide sense stationary stochastic processes in conjunction with deterministic non-uniform multi-coset sampling patterns derived from solving a weighted least square optimization problem. Next, modal properties are derived by the standard frequency domain peak picking algorithm. Special attention is focused on assessing the potential of the adopted PSBS technique, which poses no sparsity requirements to the sensed signals, to derive accurate estimates of modal structural system properties from noisy sub- Nyquist measurements. To this aim, sub-Nyquist sampled acceleration response signals corrupted by various levels of additive white noise pertaining to a benchmark space truss structure with closely spaced natural frequencies are obtained within an efficient Monte Carlo simulation-based framework. Accurate estimates of natural frequencies and reasonable estimates of local peak spectral ordinates and critical damping ratios are derived from measurements sampled at about 70% below the Nyquist rate and for SNR as low as 0db demonstrating that the adopted approach enjoys noise immunity.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing Technologies + Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2177162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Motivated by the need to reduce monetary and energy consumption costs of wireless sensor networks in undertaking output-only/operational modal analysis of engineering structures, this paper considers a multi-coset analog-toinformation converter for structural system identification from acceleration response signals of white noise excited linear damped structures sampled at sub-Nyquist rates. The underlying natural frequencies, peak gains in the frequency domain, and critical damping ratios of the vibrating structures are estimated directly from the sub-Nyquist measurements and, therefore, the computationally demanding signal reconstruction step is by-passed. This is accomplished by first employing a power spectrum blind sampling (PSBS) technique for multi-band wide sense stationary stochastic processes in conjunction with deterministic non-uniform multi-coset sampling patterns derived from solving a weighted least square optimization problem. Next, modal properties are derived by the standard frequency domain peak picking algorithm. Special attention is focused on assessing the potential of the adopted PSBS technique, which poses no sparsity requirements to the sensed signals, to derive accurate estimates of modal structural system properties from noisy sub- Nyquist measurements. To this aim, sub-Nyquist sampled acceleration response signals corrupted by various levels of additive white noise pertaining to a benchmark space truss structure with closely spaced natural frequencies are obtained within an efficient Monte Carlo simulation-based framework. Accurate estimates of natural frequencies and reasonable estimates of local peak spectral ordinates and critical damping ratios are derived from measurements sampled at about 70% below the Nyquist rate and for SNR as low as 0db demonstrating that the adopted approach enjoys noise immunity.
基于压缩功率谱感知的结构系统噪声下基于振动的纯输出系统识别
在进行工程结构的纯输出/运行模态分析时,由于需要降低无线传感器网络的货币和能源消耗成本,本文考虑了一种多协集模拟-信息转换器,用于从以亚奈奎斯特速率采样的白噪声激励线性阻尼结构的加速度响应信号中识别结构系统。底层固有频率、频域峰值增益和振动结构的临界阻尼比直接从亚奈奎斯特测量中估计,因此,计算要求高的信号重建步骤被绕过。这是通过首先采用功率谱盲采样(PSBS)技术,结合求解加权最小二乘优化问题得出的确定性非均匀多协集采样模式,实现多频带宽感知平稳随机过程。其次,通过标准频域选峰算法推导了模态特性。特别关注的是评估所采用的PSBS技术的潜力,该技术对感测信号没有稀疏性要求,可以从噪声亚奈奎斯特测量中获得模态结构系统特性的准确估计。为此,在基于蒙特卡罗仿真的有效框架内,获得了由具有紧密固有频率间隔的基准空间桁架结构的各种级别加性白噪声破坏的亚奈奎斯特采样加速度响应信号。在比奈奎斯特率低约70%、信噪比低至0db的情况下,测量得到了准确的固有频率估计值、合理的局部峰值谱坐标估计值和临界阻尼比,表明所采用的方法具有抗噪性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书