{"title":"A Novel Method to Provide Harmonics Damping to VSC-HVDC Converters","authors":"L. Souza, A. Kumar, K. Carvalho","doi":"10.1049/icp.2021.2444","DOIUrl":null,"url":null,"abstract":"This paper presents a novel method to provide harmonic damping to voltage-source converters (VSCs) applied to high voltage direct current (HVDC) transmission systems. The proposed method consists of magnetically coupling a small damping coil with a passive filter to the valve reactors. Valve reactors are connected in series with the VSC converter valves, either on the AC or DC side. So, as the added damping coil will be mutually coupled to the valve reactors, harmonic currents in the main circuit will induce currents at the corresponding frequencies in the damping circuit. The filter connected to the damping coil is designed to damp the selected range of harmonics order. The configuration and rating of passive filter/components could be varied depending upon the frequency response required. This paper further discusses the possible arrangements of the damping coil in the valve reactors to achieve enough mutual inductance. Equations to calculate the main parameters of the proposed solution are also presented. The effectiveness of the proposed solution is demonstrated through a simple test case.","PeriodicalId":347664,"journal":{"name":"The 17th International Conference on AC and DC Power Transmission (ACDC 2021)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 17th International Conference on AC and DC Power Transmission (ACDC 2021)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/icp.2021.2444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a novel method to provide harmonic damping to voltage-source converters (VSCs) applied to high voltage direct current (HVDC) transmission systems. The proposed method consists of magnetically coupling a small damping coil with a passive filter to the valve reactors. Valve reactors are connected in series with the VSC converter valves, either on the AC or DC side. So, as the added damping coil will be mutually coupled to the valve reactors, harmonic currents in the main circuit will induce currents at the corresponding frequencies in the damping circuit. The filter connected to the damping coil is designed to damp the selected range of harmonics order. The configuration and rating of passive filter/components could be varied depending upon the frequency response required. This paper further discusses the possible arrangements of the damping coil in the valve reactors to achieve enough mutual inductance. Equations to calculate the main parameters of the proposed solution are also presented. The effectiveness of the proposed solution is demonstrated through a simple test case.
一种为直流变流器提供谐波阻尼的新方法
提出了一种为高压直流输电系统中的电压源变换器(VSCs)提供谐波阻尼的新方法。所提出的方法是将带有无源滤波器的小阻尼线圈磁耦合到阀电抗器上。阀门电抗器与VSC转换阀串联连接,在交流或直流侧。因此,由于增加的阻尼线圈将与阀电抗器相互耦合,主电路中的谐波电流将感应阻尼电路中相应频率的电流。连接到阻尼线圈的滤波器用于阻尼选定范围的谐波阶数。无源滤波器/元件的配置和额定值可以根据所需的频率响应而变化。本文进一步讨论了阀式电抗器中阻尼线圈的可能布置,以获得足够的互感。给出了计算该方案主要参数的公式。通过一个简单的测试用例证明了所提出的解决方案的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信