{"title":"Korekcija određivanja položaja regulacione preklopke iz struja i napona primara i sekundara po snimljenim vrednostima pojedinačnog transformatora","authors":"S. Spremić, Danko Obradovic","doi":"10.46793/eee21-4.78s","DOIUrl":null,"url":null,"abstract":"The paper considers the possibility of direct error correction when determining the position of the control switch from the primary and secondary voltages of individual transformers that have a larger number of recorded measured values of voltage and current in a smaller or larger load range. The direct correction builds on the previously performed error correction from the voltage drop on the transformer impedance, which is used to calculate the position of the control switch using voltage. Direct correction is performed by determining the mean value of all points and then subtracting the determined mean value from the value of individual points.","PeriodicalId":236996,"journal":{"name":"Energija, ekonomija, ekologija","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energija, ekonomija, ekologija","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46793/eee21-4.78s","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paper considers the possibility of direct error correction when determining the position of the control switch from the primary and secondary voltages of individual transformers that have a larger number of recorded measured values of voltage and current in a smaller or larger load range. The direct correction builds on the previously performed error correction from the voltage drop on the transformer impedance, which is used to calculate the position of the control switch using voltage. Direct correction is performed by determining the mean value of all points and then subtracting the determined mean value from the value of individual points.
根据单台变压器的记录值,从初级和次级的电压和电压中修正调压开关的位置
本文考虑了在较小或较大负载范围内具有较多电压和电流记录测量值的单个变压器的一次电压和二次电压确定控制开关位置时直接纠错的可能性。直接校正建立在先前从变压器阻抗上的电压降进行的误差校正的基础上,这用于计算使用电压的控制开关的位置。直接校正的方法是确定所有点的平均值,然后从单个点的值中减去确定的平均值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信