Uncertainty Estimation in Luminous Flux Measured with Goniophotometers using Monte Carlo Method

Javier A. Romero R, C. Caro-Ruiz
{"title":"Uncertainty Estimation in Luminous Flux Measured with Goniophotometers using Monte Carlo Method","authors":"Javier A. Romero R, C. Caro-Ruiz","doi":"10.1109/TDLA47668.2020.9326176","DOIUrl":null,"url":null,"abstract":"When it is difficult to apply the methodology established in the GUM to calculate uncertainty in a measurement, the Monte Carlo method can be used to find an estimate of uncertainty. In this work, the Monte Carlo methodology was applied to find the uncertainty in luminous flux, when it is measured by means of a far-field goniophotometer. The methodology was applied on three light intensity matrices from three LED sources. The maximum uncertainty found is 1.2 % with a confidence level of approximately 95.5 %. By means of mathematical calculation and simulation it was determined that the distance between the light source and the sensor is the parameter that most influences the uncertainty in luminous flux.","PeriodicalId":448644,"journal":{"name":"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDLA47668.2020.9326176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

When it is difficult to apply the methodology established in the GUM to calculate uncertainty in a measurement, the Monte Carlo method can be used to find an estimate of uncertainty. In this work, the Monte Carlo methodology was applied to find the uncertainty in luminous flux, when it is measured by means of a far-field goniophotometer. The methodology was applied on three light intensity matrices from three LED sources. The maximum uncertainty found is 1.2 % with a confidence level of approximately 95.5 %. By means of mathematical calculation and simulation it was determined that the distance between the light source and the sensor is the parameter that most influences the uncertainty in luminous flux.
用蒙特卡罗法测量角形光通量的不确定度估计
当难以应用GUM中建立的方法来计算测量中的不确定度时,可以使用蒙特卡罗方法来求不确定度的估计值。在这项工作中,蒙特卡罗方法被应用于寻找光通量的不确定度,当它是由远场角差计测量。该方法应用于三个LED光源的三个光强矩阵。发现的最大不确定性为1.2%,置信水平约为95.5%。通过数学计算和仿真,确定了光源与传感器之间的距离是影响光通量不确定度最大的参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信